Related Products
IFI TCCX-2500 RF Amplifier 0.01 MHz - 220 MHz, 2.5 kW
- Digital Display Monitors: Power Supply Currents, Voltage, Forward RF Power, Reflected RF Power, (Optional on all models) Total Hours, Operate Hours
- Status Indicators: Power On, Standby, Operate
- Faults:Overcurrent, VSWR Overload, Thermal Overloads, Air Flow
IFI T84-50 TWT RF Microwave Power Amplifier
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T825-500 TWT Amplifier, 2.5 - 8GHz, 500W
- Instantaneous Broadband Frequency range
- Modular Design Construction
- Rugged Construction & High Reliability
IFI T82-500 TWT Amplifier, 2 - 8GHz, 500W
- Solid state power supply
- Instantaneous broadband frequency range
- Modular design, rugged construction, force air cooling
IFI T82-50 TWT Amplifier 2 GHz - 8 GHz, 50 Watt
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T82-300 TWT Microwave Power Amplifier, 2 GHz - 8 GHz, 300Watts
- TWT Solid State Power Supply
- Instantaneous broadband frequency range
- Modular design construction
IFI T82-250 TWT Amplifier 2 GHz - 8 GHz, 250 Watt
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T42-200 TWT Amplifier 2 GHz - 4 GHz, 200 Watt
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T4026 Millimeter RF TWT Amplifier Series
- Input/output Impedance: 50 ohms
- RF Input/ Sample Connectors: Type K Female, unless specified otherwise
- RF Output Connector: WR28 Other waveguides available by request or specification (see Option 117)
IFI T281-250 TWT Amplifier 1 GHz - 2.8 GHz, 250 Watt
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T2618-50 Millimeter TWT Amplifier | 18 – 26.5 GHz, 50 W
- Broadband, instantaneous frequency range
- Constructed with modular design
- High reliability and rugged construction
IFI T2618-40 Millimeter TWT Amplifier, 18 GHz - 26.5 GHz, 40 Watts
- VSWR power protection allows the unit to operate without oscillation or damage
- Records beam/filament elapsed time in hours
- Features RF safetylock
IFI T2618-10 TWT Amplifier 18 GHz - 26.5 GHz, 10 Watt
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T251-500A TWT Amplifier | 0.8 GHz – 2.5 GHz, 500 W
- Digital display monitors: collector current, collector voltage, helix current, helix voltage, forward rf power, reflected rf power, filament hours, beam hours
- Status indicators: power on, standby, RF on/operate
- Faults: helix overcurrent, VSWR overload, thermal overloads, air flow, collector overcurrent
IFI T251-250 High Power TWT Amplifier 1 GHz - 2.5 GHz, 250W
- Ease of Maintenance
- Designed to meet the safety requirements for the IEC-348 and Underwriters of Laboratory of American Standards
- Broadband Coverage
IFI T188-500 High Power Amplifier | 7.5 – 18 GHz, 500 W
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T188-300 TWT Amplifier | 7.5 GHz – 18 GHz, 300 W
- Frequency Range: 7.5-18GHz
- Min Power Out: 300 Watts
- Min Sat Gain: 55dB
IFI T186-60 TWT Amplifier 6 GHz - 18 GHz, 60W
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T186-50 TWT Amplifier | 6 GHz – 18 GHz, 50 W
- Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours
- Status Indicators: Power On, Standby, RF On/Operate
- Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
IFI T-1000 Series High Power, RF Microwave, TWT Amplifiers
- Input/output Impedance: 50 ohms
- RF Input/ Sample Connectors: Type N Female, unless specified otherwise
- RF Output Connector: Type 716 Female up to 7.5 GHz, 4 – 8 GHz is WRD350 8 – 12 GHz is WR90, 12 – 18 GHz is WR62, 7.5 – 18 GHz is WRD750, 6.5 – 18 GHz is WRD650 Other
IFI ST81-50 Solid State/TWT (CW) Amplifier 1.0 GHz - 8.0 GHz, 50 Watt
- VSWR Protection against an output mismatch
- Alternate Prime Power
- GPIB IEEE 488 Remote Control
IFI SMX100 Solid State Power Amplifier | 10 kHz - 1 GHz, 100 W
- Digital Display Monitors: Power Supply Currents, Voltage, Forward RF Power, Reflected RF Power, (Optional on CMX Models) Total Hours, Operate Hours
- Status Indicators: Power On, Standby, Operate
- Faults: Overcurrent, VSWR Overload, Thermal Overloads, Air Flow Power Supply
IFI SMIV-1000 Amplifier for HIRF Testing, 400 MHz - 1000 MHz, 1000W
- Input/output Impedance: 50 ohms
- RF Input/ Sample Connectors: Type N Female, unless specified otherwise
- RF Output Connector: Type N Female up to 1KW amps, SC or 7/16 available, 7/16 2KW/3KW/5KW amps. Other connectors available by request or specification
IFI SMCC500 Solid State Amplifier
- VSWR Reflected Power Protection
- Open and Short Circuit Protection
- GPIB IEEE 488 and RS232 Remote Control
IFI SMCC250 Solid State Amplifier
- VSWR Reflected Power Protection
- Open and Short Circuit Protection
- GPIB IEEE 488 and RS232 Remote Control