A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MX Compliance Test System (MXCTS) provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards.
 
CTSH High Power Test Standards System:
 
  • PACS-3-75 Measurement system. Mounted in OMNI-3-75 cabinet.
  • OMNI-3-75 Three phase Lumped impedance cabinet for IEC 61000-3-11 Flicker
  • CIC651 CTSMXH Software for IEC 61000-3-12 (Harmonics and IEC 61000-3-11 (Flicker) testing. (P/N CIC651)
  • CI400PCI A/D Card PCI Bus.
  • CI68C Cable from CI400PCI to PACS-3-75.
 
CTSL Low Power Test Standards System:
 
  • PACS-3-75 Measurement system. Mounted in OMNI-3-75 cabinet.
  • OMNI-3-37MX Three phase Lumped impedance for IEC 61000-3-3 Flicker
  • CIC652 CTSMXL Software for IEC 61000-3-2 (Harmonics and IEC 61000-3-3 (Flicker) testing. (P/N CIC652)
  • CI400PCI A/D Card PCI Bus.
  • CI68C Cable from CI400PCI to PACS-3-75.
  • Cabinet 42” cabinet with PACS-3-75 and OMNI-3-37MX installed.

CTSHL High and Low Power Test Standards:
 
  • Combines CTSH and CTSL components.
 

Features:

 
  • Direct PC bus access data acquisition system provides the required sampling rate and resolution to meet IEC 61000-4-7 measurement requirements and supports high speed data transfers, unlike competing IEC test systems
    which provide only limited throughput using IEEE-488.
  • PC based Harmonic and Flicker test software provides real-time full color data display updates and continuous PASS/FAIL monitoring.
  • Automatic calculation of the maximum permissible system impedance Zsys, using the Zref and measured Flicker parameters, as required per
    EN/IEC 61000-3-11.
  • Simple user operation under Windows provides IEC test setup, data analysis, display and MS Word test reports.
  • High resolution, no gap acquisition data storage to ensure that all data can be streamed to disk (in ASCII format if needed) for later review and replay of actual test.
  • Single Step and Fast playback mode of test results
  • Compliance Testing to: EN / IEC 61000-3-12, -3-11, -3-2, -3-3, -4-13 (option), -4-14, -4-17, -4-28
  • Pre-compliance Testing to: EN / IEC 61000-4-11 (option), -4-27, -4-29
     
 

Specifications:

 
Parameters: PACS-3-75
Number of phases: 3
Channels: 6
Connector Style: Rear panel compression terminal block
Maximum voltage: 480 Vac
Maximum current: 75 Arms/phase
Input Power Voltage: 115 / 230 V ± 10 %
Input Power Current: < 0.75 A
Input Power Frequency: 50 / 60 Hz
Dimensions HxWxD: 5.25” x 16.8” x 22”