EM Test CWS 500N1 Continuous Wave Simulator, 80W

Rent EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6
Enlarge Image
Rent EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6 Rent EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6
EM Test CWS500N1
Request Quote Print Page
Datasheet Accessory Kit

The CWS 500N1 Continuous Wave Simulator is the most compact single box test equipment for testing conducted rf immunity as per IEC 61000-4-6, 60601-1-2, and related standards with a frequency range of 100kHz to 300MHz. Apart from the 1kHz 80% AM signal the CWS 500N1 also generates a 2 Hz 80% AM signal to test medical appliances and a 1 Hz PM signal with 50% duty cycle required to test safety equipment like fire alarms. Equipped with a 1 GHz current monitor the CWS 500N1 can be used up to 1 GHz by means of an external amplifier.
 

EM TEST supplies a large range of CDNs, EM clamp and current injection clamps as well as the corresponding calibration accessories. Full compliant levelling can be run from the front panel of the CWS 500N1 storing the results in 5 memory spaces available in the CWS 500N1.

 

Features:

  • Signal generator 9kHz to 1GHz
  • Amplitude modulation: 1Hz to 3kHz (0% to 95%)
  • Pulse modulation: 1Hz - 1kHz (10% to 90%)
  • Built-in amplifier, 100kHz to 300MHz
  • Built-in current monitor, 9kHz to 1GHz

 

Specifications:

Test Level
Output level 1V - max. 30V (emf) all standard test levels are guaranteed with all coupling methods
Output power 80W (nominal)
Output impedance 50ohm
Harmonic Distortion < -20dBc at max.power
Test Frequencies
Sinus (CW) 100kHz to 300MHz
Frequency bands 100kHz to 9.999MHz
10MHz to 99.99MHz
100MHz to 300MHz
in the Quick Start menu the step size can be selected by the operator
Unmodulated signal CW (continuous wave)
Amplitude modulation 1kHz, 80%AM as per IEC 61000-4-6
2Hz, 80%AM as per IEC 60601-1-2
400Hz, 80%AM
Pulse modulation 1Hz, 50% duty cycle as per EN 50130-4
Measurements
Monitor Integrated RF power meter, measuring input for CDN and clamp calibration as well as current monitor for clamp applications
RF indicator LED indicating the RF output status
LCD Online display of the test level and the preselected frequency value
Cal data F1 - F5 5 internal memories to save calibration data, 1% step width as required by the standard
Time Paramenters
Dwell time for CW & AM td = 0.3s to 9,999s
Dwell time for PM td = 3s to 9,999s
Pause time tr = 0/0.3s to 9,999s
tr = 0/0.3s to 9,999s
Direct RF output BNC (on the front panel)
Test Routines
Quick Start Immediate test start; easy-to-use and fast
User Test routines Voltage sweep
Frequency sweep
Dwell time sweep
Standard Test routines Level 1 to Level 3 (IEC 61000-4-6) Automatic Level X to Level Y
Cal procedure Calibration of the complete test set-up, calibration data saved in internal memory
Service Service, set-up
SIGNAL GENERATOR
Output level -55dBm to 0dBm
Frequency range 9kHz to 1GHz
Output impedance 50ohm
Direct RF output To control an external amplifier
General Data
Dimensions, weight 19"/3HU, approx. 17kg
Supply voltage 115V to 230V +10/-15%, 50/60Hz
Input power Max. 380W
Power factor cos (phi) = 0.98 at max. output power as per IEC 555
Fuses 2 x 6.3AT (115V) or 2 x 3.15AT (230V)
Cooling Active cooling, air ventilation
Temperature 10°C to 40°C
Rel. humidity Max. 85%, non condensing
 

Applications:

  • Industry
  • Medical
  • Broadcast
  • Telecom
  • Residential
  • Renewable Energy

 

Options:
ATT6/75 6dB attenuator, 75W
ATT20/0.5 20dB attenuator, 0.5W for the calibration of CDNs and clamps (included with the PM 1000)
CDNs As per IEC 61000-4-6 (refer to separate list)
Clamps EM clamp as per IEC 61000-4-6
Current injection clamps
Current monitoring clamps
T-50 50ohm termination resistor for CDNs and clamps
R-100N 150ohm-to-50ohm matching impedance with CDN- and EM-clamp calibration
R-100A 150ohm-to-50ohm matching impedance with N-type connector with BCI-clamp calibration
Cal adapters For all types of CDNs and clamps
icd.control Extensive and most versatile remote control and reporting software.
A standard library helps to configure the test setup.
Multiple interruption functions automated by IEEE instruments or
manually.
Easy to use or expandable to complex test routines on the base of
vector definitions.