LOAD DUMP TEST 1 AS PER 5.5.3 |
Voltage (o.c.) | 80V ± 2V |
Rise time | < 10us |
Pulse duration | 52us ± 5us (measured at tau) |
Output resistor | 2.5ohm |
Polarity | Positive |
Repetition time | 1 pulse each 5ms |
Test time | 10min |
Coupling | Superimposed to the battery supply line |
LOAD DUMP TEST 2 - GIANT PULSE - AS PER 5.5.4 |
Voltages (o.c.) | 50V ± 2V 80V ± 2V 110V ± 2V |
Rise time | < 1ms |
Pulse duration | 188ms ± 4ms (measured at tau) |
Output resistor | 2.5ohm |
Polarity | Positive |
Repetition time | 1 pulse per minute |
Coupling | Superimposed to the battery supply line |
LOAD DUMP TEST 3 - HIGH REPETITIVE LOAD DUMP AS PER 5.5.5 |
Voltage (o.c.) | 80V ± 2V |
Rise time | < 10us |
Pulse duration | 52us ± 5us (measured at tau) |
Output resistor | 2.5ohm |
Polarity | Positive |
Repetition time | 1 pulse each 5ms |
Positive pole surge | +30V +0V/-1V |
Duration | 300ms |
Repetition time | 1 pulse per minute |
Control | DC supply controlled by LD 200S19 |
Coupling | Superimposed to the battery supply line |
TRIGGER |
Automatic | Automatic pulse release |
Counter | 1 - 1,000,000 |
Battery supply | Max. 60V/50A with 100A inrush current External DC source or battery is requested |
Superimposed | + line |
Decoupled | By diode network |
GENERAL DATA |
Dimensions, weight | 19"/6HU, approx. 18kg |
Supply voltage | 115/230V +10/-15% |
Fuses | 2 x 1AT |