Related Products

Dranetz HDPQ Visa Power Quality & Energy Monitoring Analyzer
- High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle
- Eight channels, 4 voltage & 4 current
- Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant


Dranetz HDPQ Xplorer Power Quality Analyzer
- High definition PQ & energy monitoring: 1000 Vrms, AC / DC, 512 samples/cycle
- High speed digitized transients to 1us – to 2000Vpk
- Eight channels, 4 voltage & 4 current


Fluke 1736 Three-Phase Power Logger
- Voltage range: 100 - 240V (standard)
- Power consumption: 50VA Max
- Frequency: 42.5 to 69Hz

Dranetz HDPQ Xplorer Plus Power Quality Analyzer
- High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle
- High Speed Digitized Transients – 1us, 10 to 2000Vpk
- Transient triggers – V & I – waveshape triggers, high speed. Well beyond PQ standards requirements


Dranetz HDPQ Guide Power Quality Analyzer
- High definition PQ & energy monitoring: 1000 Vrms, AC/DC, 512 samples/cycle
- Eight channels, 4 voltage & 4 current
- AnswerModules: sag directivity, PF capacitor identification, motor: automatic event categorization


Fluke 1777 Three-Phase Power Quality Analyzer
- Voltage: 100V – 600V (-15% / +10%)
- Power Consumption: 40VA Max
- Bandwidth: DC to 30 kHz

Fluke 437-II Three-Phase Power Quality Analyzer
- Energy loss calculator: quantified to pinpoint true system energy losses in dollars
- Power inverter efficiency: simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp
- Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics

Fluke 1738 Advanced Power Logger
- Voltage range: 100 - 240V (standard)
- Power consumption: 50VA Max
- Bandwidth: 42.5Hz - 3.5kHz

AEMC PowerPad IV Model 8345 Power Quality Analyzer
- Full compliance with IEC 61000-4-30 ed. 3.0 Class A functions
- Real-time display of color waveforms (5 voltage/4 current) from 1 cycle to 10/12 cycles
- Calculation of unbalance (current and voltage)


Dranetz HDPQ Visa Plus
- Frequency | 16 - 25 Hz, 42.5 - 69 Hz, ±0.01 Hz
- Harmonics | IEC 61000-4-6, IEEE 519:2014
- Real power (W) | P: meets 0.2S requirements


Fluke 1775 Three-Phase Power Quality Analyzer
- Automatically measure power and power quality parameters
- At-a-glance power quality health for faster troubleshooting
- Easily view V/A/Hz, power, dips, swells, and harmonics data

Fluke 438-II Power Quality Analyzer & Motor Analyzer
- Measure key parameters on direct-on-line motors and motors driven by specific variable frequency drive systems including torque, RPM, mechanical power and motor efficiency
- Perform dynamic motor analysis by plotting of motor de-rating factor against load according to NEMA guidelines
- Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you’re ready to go

Dranetz DranXperT
- DranXperT Power Logger with 4 Flex Current Probes 16-inch, 1500 A
- PQ disturbance/event detector, power/energy logger, and sensor logger
- 3 voltage channels – direct measurements up to 600 Vrms, CAT III


Fluke 1760 Three-Phase Power Quality Recorder Topas
- Fully Class-A compliant
- GPS time synchronization
- Flexible and fully configurable thresholds and scale factors

Dranetz HDPQ Guide SP Power Quality Analyzer
- IP65 enclosure
- GPS
- High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle


Fluke 1664 FC Installation Multifunction Tester
- Multifunction tester that tests to all local regulations
- Includes "Insulation Pre-test" that detects when appliances are connected to the system and stops the test
- Runs seven installation tests automatically in one sequence with a single connection through Auto Test

Fluke 1730 Three-Phase Electrical Energy Logger
- Key measurements: Voltage, current, power, power factor and associated values enable you to optimize and implement your energy saving strategies.
- Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display.
- Comprehensive logging: More than 20 separate logging sessions can be stored on the instrument. In fact, all measured values are automatically logged and can be reviewed during logging and before

AEMC PEL 103
- Simple to use, single-, dual- (split-phase) and three-phase (Y, ∆) power & energy loggers
- Provides all the necessary functions for Power and Energy data logging for 50Hz, 60Hz, 400Hz and DC distribution systems
- Current measurements from 200mA up to 10,000A using flexible current sensors


Fluke 1735 Three-Phase Power Logger
- Record power and associated parameters for up to 45 days
- Monitor maximum power demand over user-defined averaging periods
- Efficiency improvements with energy consumption tests

Megger MPQ2000 Portable Power Quality Analyzer
- Power off Phase A or auxiliary, allowing it to be used anywhere without an AC outlet
- Weather proof to NEMA 4 standard for use in any environment
- Auto CT identifies the current that the instrument is connected to and the range that it is in

Dranetz PX5-400 Power Analyzer
- Tests at 50/60 and 400Hz
- Meets MIL Standard 1399 testing
- Eight channels, 4 voltage & 4 current


Hioki PW3360 Clamp On Power Logger
- Supports single to three-phase, 4-wire circuits
- Measure between 90V to 780V
- Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)


Fluke RPM 1650 Power Recorder
- The sampling system processes every cycle on all channels, recording min/max/avg values and looking for sags, swells, or transients.
- The system can store 6000 events (up to 96,000 withMultisession Option). You can see everything from sub-cycle events to long-term outages with clear detail.
- Records power parameters, RMS voltage, RMS current, harmonics, flicker and monitors for power quality events on all channels simultaneously without havingto reconfigure.

Fluke 375 True-RMS AC-DC Clamp Meter
- iFlex flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
- CAT IV 600 V, CAT III 1000 V
- True-rms ac voltage and current for accurate measurements on non-linear signals

Hioki 3169-20 Clamp-On Power HiTester
- Measure up to 3-phase, 3-wire system (displays voltage and current for three lines)
- Measure up to four single-phase, 2-wire systems
- 5A to 5000A range