Solar 9354-2 Transient Generator for MIL-STD-461 and DO-160

Rent Solar 9354-2 Transient Generator for MIL-STD-461D/E CS116, MIL-STD-461C CS10 and CS11, DO-160D Section 22
Enlarge Image
Rent Solar 9354-2 Transient Generator for MIL-STD-461D/E CS116, MIL-STD-461C CS10 and CS11, DO-160D Section 22 Rent Solar 9354-2 Transient Generator for MIL-STD-461D/E CS116, MIL-STD-461C CS10 and CS11, DO-160D Section 22 Rent Solar 9354-2 Transient Generator for MIL-STD-461D/E CS116, MIL-STD-461C CS10 and CS11, DO-160D Section 22
Solar Electronics 9354-2
Request Quote Print Page
Datasheet Accessory Kit

The Model 9354-2 Transient Generator was especially designed for the performance of a variety of pulse susceptibility tests on sub-systems and/or equipment, in accordance with MIL-STD-461D/E, method CS116; also capable of testing for RTCA DO160D, section 22; MIL-STD-461C, methods CS10 and CS11.
 

The 9354-2 provides nine selectable waveforms, including six damped sinusoidal pulses (10 KHz, 100 KHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) and three double exponential pulses (6.4 µS, 70 µS, and 120 µS).
 

Through the use of many Solar accessories, including various reactive networks and coupling devices, as well as other commercially available items such as loop antennas, parallel plates, and TEM cells, the generated output may be modified and applied to other specifications.
 

Accessories:
Type 9335-2
Universal Coupling Device
An inductive injection device that provides voltage and current transfer of 1:1, 1:1.5 and 3:1 voltage
step-up (current step-down) as well as 2:1 voltage
step-down (current step-up)
Type 9719-1N
Injection Probe
Provides the required current leveles of MIL-STD-461D and E, method CS116 throughout the entire frequency
range of 10 KHz to 100 MHz
Type 9357-1
Calibration Fixture
Calibration fixture provides a 50 ohm characteristic
impedance based on the dimensions of the Type 9335-2 Universal Coupling Device and Type 9719-1N Injection Probe. The fixture maintains a low standing wave ratio from 10 KHz to 100 MHz in a 50 ohm circuit.
Type 9142-1N
Injection Probe
Used to inject current on cables from 1 MHz to 100 MHz.
Type 9125-1
Calibration Fixture
Calibration fixture for use with Type 9142-1N Injection
Probe
Type 9123-1N
Current Probe
Used to monitor injected pulses. Frequency range from 10 KHz to 500 MHz
Type 9410-1
50
/50
and
Type 9454-1
600
/50
High Voltage Attenuators
Provides 40 dB attenuation from 10 KHz to 100 MHz. Protects oscilloscope from high voltage damage when verifying the output pulses of the Model 9354-2. The Type 9454-1 provides a high impedance to the oscilloscope for making measurements of open circuit output pulses
Type 6220-4
High Voltage Audio Isolation Transformer
When connected in series with the power lead under test, provides twice the open circuit voltage or twice the short circuit current for the 10 KHz and 100 MHz damped sinusoid waves and the 6.4 S and 70 S double exponential pulses. Capable of handling up to 4000 volts
Type 9616-1
Injection Clamp
Provides coupling for high voltage pulses produced by the Model 9354-2. Meets the inductive indirect injection device requirement of MIL-STD-462, notice 5, method CS10 and CS11. Enables injection of 70 S double exponential pulses without need for direct connection.


Features:

  • Panel-mounted digital voltmeter. Monitors the adjusted open circuit discharge voltage
  • Pulse rates up to one pulse per second maximum (factory adjusted)
  • Single pulse feature enables controlled isolation of transient effects
  • Output voltage adjustable from 0.1% to 100% of selected discharge voltage