Solar 9354-1 Transient Generator for MIL-STD-461 CS116

Rent Solar 9354-1 10 kHz - 100 MHz Transient Generator for susceptibility tests MIL-STD461C/D/E CS116, DO-160C/D Section 22
Enlarge Image
Rent Solar 9354-1 10 kHz - 100 MHz Transient Generator for susceptibility tests MIL-STD461C/D/E CS116, DO-160C/D Section 22 Rent Solar 9354-1 10 kHz - 100 MHz Transient Generator for susceptibility tests MIL-STD461C/D/E CS116, DO-160C/D Section 22
Solar Electronics 9354-1
Request Quote Print Page
Datasheet Accessory Kit

The Solar Model 9354-1 Universal Transient Generator provides nine selectable waveforms, including six damped sinusoidal pulses (10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) and three double exponential pulses (6.4 µS, 70 µS, 500 µS).
 

The Solar 9354-1 Transient Generator was especially designed for the performance of a variety of pulse susceptibility tests on subsystems and/or equipment, in accordance with MIL-STD-461D and E, method CS116; RTCA DO160D, section 22; MIL-STD-461C, methods CS10 and CS11.
 

Through the use of many Solar accessories, including various reactive networks and coupling devices, as well as other commercially available items such as loop antennas, parallel plates, and TEM cells, the generated output may be modified and applied to other specifications.
 
Solar Electronics 9354-1 Features
  • Panel mounted digital Voltmeter displays the open circuit discharge voltage
  • Automatic or manual trigger for damped sinewave. Manual only for double exponential pulses
  • Variable peak output voltage (adjustable from 0.1 to 100% of selected circuit discharge voltage
  • An independent circuit for each waveform improves reliability, simplifies maintenance, and allows for customized waveforms and output impedances
  • Solid state switching and RC networks across coils, switches, and relay contacts to reduce arcing, eliminate contact bounce, and increase component life
Solar Electronics 9354-1 Specs
Damped Sinusoid
10 kHz Open Circuit Voltage: 30.0 V
Source Impedance: < 0.25 ohms
100 kHz Open Circuit Voltage: 150.0 V
Source Impedance: < 3.8 ohms
1 MHz Open Circuit Voltage: 3200.0 V
Source Impedance: < 28.0 ohms
10 MHz Open Circuit Voltage: 3200.0 V
Source Impedance: < 39.0 ohms
30 MHz Open Circuit Voltage: 1000.0 V
Source Impedance: < 50.0 ohms
100 MHz Open Circuit Voltage: 300.0 V
Source Impedance: < 50.0 ohms
 
Double Exponential
6.4 µS Rise Time: 100 nS
Open Circuit Voltage: 1600 V
Source Impedance: < 2.0 ohms
70.0 µS Rise Time: 6.4 nS
Open Circuit Voltage: 1600 V
Source Impedance: < 2.0 ohms
500.0 µS Rise Time: 50 nS
Open Circuit Voltage: 1600 V
Source Impedance: < 4.0 ohms
Solar Electronics 9354-1 Applications
  • The six damped sinusoidal waveforms meet the requirements of MIL-STD-461D, CS116, when applied in accordance with the corresponding test method of MIL-STD-462D. These same waveforms are applicable to the requirements of MIL-STD-461C, CS10 & CS11 when applied with the test method of MIL-STD-462, Notice 5
  • Extended limits: Two of the six damped sinusoidal waveforms (1 MHz and 10 MHz) have their limits extended to an open circuit voltage of 3200 volts peak to meet the requirements of DO-160, Section 22, Table 22-2
  • Double exponential: The double exponential pulses were specifically designed to meet the requirements of DO-160C, Section 22
Solar Electronics 9354-1 Accessories
Type 9335-2
Universal Coupling Device
An inductive injection device that provides voltage and current transfer of 1:1, 1:1.5 and 3:1 voltage
step-up (current step-down) as well as 2:1 voltage
step-down (current step-up)
Type 9719-1N
Injection Probe
Provides the required current levels of MIL-STD-461D and E, method CS116 throughout the entire frequency
range of 10 KHz to 100 MHz
Type 9357-1
Calibration Fixture
Calibration fixture provides a 50 ohm characteristic
impedance based on the dimensions of the Type 9335-2 Universal Coupling Device and Type 9719-1N Injection Probe. The fixture maintains a low standing wave ratio from 10 KHz to 100 MHz in a 50 ohm circuit.
Type 9142-1N
Injection Probe
Used to inject current on cables from 1 MHz to 100 MHz.
Type 9125-1
Calibration Fixture
Calibration fixture for use with Type 9142-1N Injection
Probe
Type 9123-1N
Current Probe
Used to monitor injected pulses. Frequency range from 10 KHz to 500 MHz
Type 9410-1
50Ω/50Ω
and
Type 9454-1
600Ω/50Ω
High Voltage Attenuators
Provides 40 dB attenuation from 10 KHz to 100 MHz. Protects oscilloscope from high voltage damage when verifying the output pulses of the Model 9354-1. The Type 9454-1 provides a high impedance to the oscilloscope for making measurements of open circuit output pulses
Type 6220-4
High Voltage Audio Isolation Transformer
When connected in series with the power lead under test, provides twice the open circuit voltage or twice the short circuit current for the 10 KHz and 100 MHz damped sinusoid waves and the 6.4 S and 70 S double exponential pulses. Capable of handling up to 4000 volts
Type 9616-1
Injection Clamp
Provides coupling for high voltage pulses produced by the Model 9354-1. Meets the inductive indirect injection device requirement of MIL-STD-462, notice 5, method CS10 and CS11. Enables injection of 70 S double exponential pulses without need for direct connection.