IEC 60270 Standard Overview
IEC 60270 – partial discharge measurements (previously high voltage test techniques) – is applicable to the measurement of partial discharge which occurs in electrical apparatus, systems, and components when tested with DC voltage or AC voltage up to 400 Hz.
Related Standards:
IEC 60060-1, High-voltage test techniques – Part 1: General definitions and test requirements
IEC 60060-2, High-voltage test techniques – Part 2: Measuring Systems
CISPR 16-1:1993, Specification for radio disturbance and immunity measuring apparatus and methods – Part 1: Radio disturbance and immunity measuring apparatus
Introduction to Partial Discharge Testing
Partial discharge is a major factor in insulation failure and the failure of electrical equipment like power transformers, HV cables, switchgear, motors and generators. PD measurement allowsoperators to perform effective and reliable insulation testing of these high voltage devices in applications like factory acceptance testing, on-site commissioning and routine electrical maintenance. PD analysis techniques must adhere to IEC 60270, the international standard for the measurement of electrical discharges in insulation.
Partial discharge testing, or PD testing, detects the presence of partial discharges in high voltage equipment. A partial discharge (PD) is a small spark within electrical insulation caused by insulation breakdown. PDs occur when an electrical insulation system experiences HV stress; a dielectric breakdown of a small portion of the insulation generates electrical discharges, which bridge the gap between two conducting electrodes. These dielectric breakdowns manifest across the surface of insulation material, in pockets found in solid insulation, within gas bubbles in liquid forms of insulation and proximal to electrodes in gases. As aging HV equipment continues to operate at high levels all around us, PD testing is more critical than ever to diagnose insulation failure before electrical stress shuts systems down and incurs expensive maintenance.
Basic Test Equipment Requirements:
Technical committees are recommended to use apparent charge as the measured quantity wherever possible. Other quantities may be used if the apparent charge is not appropriate for a given situation.
Partial Discharge Pulse (PD Pulse) – A voltage or current pulse resulting from a partial discharge occurring within the DUT (device under test). Appropriate detection circuits are introduced to the circuit to measure the pulse.
Discharge Mechanism – "PD usually begins within voids, cracks, or inclusions within a solid dielectric, at conductor-dielectric interfaces within solid or liquid dielectrics, or in bubbles within liquid dielectrics. Since PDs are limited to only a portion of the insulation, the discharges only partially bridge the distance between electrodes. PD can also occur along the boundary between different insulating materials. Partial discharges within an insulating material are usually initiated within gas-filled voids within the dielectric. Because the dielectric constant of the void is considerably less than the surrounding dielectric, the electric field across the void is significantly higher than across an equivalent distance of dielectric. If the voltage stress across the void is increased above the corona inception voltage (CIV) for the gas within the void, then PD activity will start within the void.
Related Standards:
IEC 60060-1, High-voltage test techniques – Part 1: General definitions and test requirements
IEC 60060-2, High-voltage test techniques – Part 2: Measuring Systems
CISPR 16-1:1993, Specification for radio disturbance and immunity measuring apparatus and methods – Part 1: Radio disturbance and immunity measuring apparatus
Introduction to Partial Discharge Testing
Partial discharge is a major factor in insulation failure and the failure of electrical equipment like power transformers, HV cables, switchgear, motors and generators. PD measurement allowsoperators to perform effective and reliable insulation testing of these high voltage devices in applications like factory acceptance testing, on-site commissioning and routine electrical maintenance. PD analysis techniques must adhere to IEC 60270, the international standard for the measurement of electrical discharges in insulation.
Partial discharge testing, or PD testing, detects the presence of partial discharges in high voltage equipment. A partial discharge (PD) is a small spark within electrical insulation caused by insulation breakdown. PDs occur when an electrical insulation system experiences HV stress; a dielectric breakdown of a small portion of the insulation generates electrical discharges, which bridge the gap between two conducting electrodes. These dielectric breakdowns manifest across the surface of insulation material, in pockets found in solid insulation, within gas bubbles in liquid forms of insulation and proximal to electrodes in gases. As aging HV equipment continues to operate at high levels all around us, PD testing is more critical than ever to diagnose insulation failure before electrical stress shuts systems down and incurs expensive maintenance.
Basic Test Equipment Requirements:
Technical committees are recommended to use apparent charge as the measured quantity wherever possible. Other quantities may be used if the apparent charge is not appropriate for a given situation.
- High-voltage power supply with low background noise
- High-voltage connections
- Measuring system with known input impedance
- An impedance or filter for reducing background noise
- Coupling capacitor with low inductance
- Test object (usually denoted as a capacitor)
Partial Discharge Pulse (PD Pulse) – A voltage or current pulse resulting from a partial discharge occurring within the DUT (device under test). Appropriate detection circuits are introduced to the circuit to measure the pulse.
Discharge Mechanism – "PD usually begins within voids, cracks, or inclusions within a solid dielectric, at conductor-dielectric interfaces within solid or liquid dielectrics, or in bubbles within liquid dielectrics. Since PDs are limited to only a portion of the insulation, the discharges only partially bridge the distance between electrodes. PD can also occur along the boundary between different insulating materials. Partial discharges within an insulating material are usually initiated within gas-filled voids within the dielectric. Because the dielectric constant of the void is considerably less than the surrounding dielectric, the electric field across the void is significantly higher than across an equivalent distance of dielectric. If the voltage stress across the void is increased above the corona inception voltage (CIV) for the gas within the void, then PD activity will start within the void.
Related IEC Standards
Explore All Standards
IEC 60050-444 International Electrotechnical Vocabulary Part 444: Elementary Relays
IEC 60255: Electrical Relays
IEC 60533: EMC Testing of Ships with Metallic Hulls
IEC 60601-1-2: Medical Electrical Equipment - Collateral standard: Electromagnetic compatibility...
IEC 61000-3-2: Limits - Limits for Harmonic Current Emissions (equipment input current up to and...
IEC 61000-3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public...
IEC 61000-3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker...
IEC 61000-3-12: Limits for harmonic currents produced by equipment connected to public...
IEC 61000-3-13: Electromagnetic compatibility (EMC) Limits - Assessment of emission limits for...
IEC 61000-4-2: Electrostatic Discharge Immunity Test
IEC 61000-4-3: Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4: Electrical Fast Transient (EFT) / EMC Burst Immunity Test Standard
IEC 61000-4-5: Testing and Measurement techniques - Surge Immunity Test
IEC 61000-4-6: Immunity to Conducted Disturbances, Induced by Radio Frequency Fields
IEC 61000-4-7: General Guide on Harmonics and Interharmonics Measurements and Instrumentation
IEC 61000-4-8 Electromagnetic Compatibility (EMC) - Part 4-8: Testing and Measurement Techniques...
IEC 61000-4-9 Electromagnetic Compatibility (EMC) - Part 4-9: Testing and Measurement Techniques...
IEC 61000-4-10: Testing and Measurement Techniques Damped Oscillatory Magnetic Field Immunity Test
IEC 61000-4-11: Testing and Measurement Techniques - Voltage Dips, Short Interruptions and...
IEC 61000-4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-13: Testing and measurement techniques - Harmonics and interharmonics including mains...
IEC 61000-4-14: Testing and measurement techniques - Voltage fluctuation immunity test
IEC 61000-4-15: Testing and Measurement Techniques - Flickermeter. Functional and Design...
IEC 61000-4-16: Testing and Measurement Techniques – Test for Immunity to Conducted, Common Mode...
IEC 61000-4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
IEC 61000-4-18: Testing and measurement techniques – Damped oscillatory wave immunity test
IEC 61000-4-19: Test for Immunity to Conducted, Differential Mode Disturbances and Signaling
IEC 61000-4-20 Electromagnetic compatibility (EMC) – Part 4-20: Testing and measurement techniques...
IEC 61000-4-21 Electromagnetic compatibility (EMC) Part 4-21: Testing and measurement techniques...
IEC 61000-4-27: Unbalance, immunity test
IEC 61000-4-28: Testing and measurement techniques - Variation of power frequency, immunity test
IEC 61000-4-29 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement...
IEC 61000-4-30: Testing and Measurement Techniques - Power Quality Measurement Methods.
IEC 61000-4-31: Testing and measurement techniques - AC mains ports broadband conducted disturbance
IEC 61000-4-34: Testing and Measurement Techniques - Voltage Dips, Short Interruptions...
IEC 61000-4-39:2017: Electromagnetic Compatibility Immunity Requirements
IEC 61000-6-2: Immunity Testing of Industrial Equipment
IEC 61000-6-4: Emission standard for industrial environments
IEC 61000-6-5: Immunity for Power Station and Substation Environments
IEC 61010-1: Safety of Measuring, Control and Laboratory Equipment
IEC 61326: EMC Testing of Laboratory Equipment
IEC 61340-3-1: Methods for Replication of Electrostatic Effects - Human Body Model (HBM)...
IEC 61340-3-2: Methods for Replication of Electrostatic Effects – Machine Model (MM)...
IEC 61672-1: Electroacoustics – Sound level meters – Part 1: Specifications
IEC 61672-2: Electroacoustics – Sound level meters – Part 2: Pattern evaluation tests
IEC 61672-3: Electroacoustics – Sound level meters – Part 3: Periodic tests
IEC 61850: Communication Networks and Systems in Substations
IEC 62037: Passive RF and Microwave Devices, Intermodulation Level Measurement
IEC 62233: Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human
IEC 62619: Safety Requirements for Secondary Lithium Cells and Batteries, for Use in Industrial Applications
IEC 62764-1: Low-Frequency Magnetic Fields