Model Number |
9510-50 |
9510-75 |
9510-100 |
9510-200 |
9510-300 |
9510-400 |
9510-500 |
9510-1000 |
9510-1200 |
Description |
50kW |
75kW |
100kW |
(Only 100kW cabinet can support parallel expansion up to 1.2MW3) |
AC Output Ratings |
Operating Modes |
4-Quadrant with Programmable Voltage (CV), Power Amplifier (PHIL), Optional AC Load |
Output Configurations |
Independent set per channel 3x 1Φ (AC or DC), 2Φ + 1Φ (AC or DC), or 3Φ AC outputs |
Power, Max (1Φ or 3Φ) |
50kW/
118kVA |
75kW/
177kVA |
100kW/
236kVA |
200kW/
472kVA |
300kW/
708kVA |
400kW/
945kVA |
500kW/
1181kVA |
1000kW/
2362kVA |
1200kW/
2835kVA |
Current Ranges (RMS per Φ) |
25, 112.5 A |
650, 168 A |
50, 225 A |
100, 450 A |
150, 675 A |
200, 900 A |
250, 1125 A |
500, 2250 A |
600, 2700 A |
Current Ranges (RMS 1Φ Mode) |
75, 337.5A |
150, 506A |
150, 675A |
300, 1350A |
450, 2025A |
7600, 2700A |
750, 3375A |
1500, 6750A |
1800, 8100A |
Frequency |
30 – 120Hz (10 mHz resolution) |
Voltage Ranges |
10 - 175, 10 - 350VRMS L-N (Split Phase 10-125, 20-250V Max) |
Voltage Accuracy |
± 0.1% F.S. |
Programming Resolution |
0.01V |
Load Regulation |
± 0.02% |
Distortion (THD)1 |
0.45% (Typical) 0.65% (Max) <70Hz no load to full load ; 0.6% (Typical) 0.85% (Max) >70Hz no load to full load |
Slew Rate |
1V/μS (10% to 90% measured at 90 degree turn-on into resistive load) |
Waveforms |
Sine, n-Step Sine, Triangle, Clipped-Sine, Arbitrary (user defined) |
Phase Angle Control |
0 to 359 degrees/1 degree resolution |
DC Output Ratings |
Operating Modes |
DC Constant Voltage (CV), Constant Current (CC), Constant Power (CP), Power Amplifier (PHIL), Optional DC Load |
Power Max (1ch or 3ch) |
50 kW |
75 kW |
100 kW |
200 kW |
300 kW |
400 kW |
500 kW |
1000 kW |
1200 kW |
Current Ranges (Per Ch.) |
25, 100A |
50, 150A |
50, 200A |
100, 400A |
150, 600A |
200, 800A |
250, 1000A |
500, 2000A |
600, 2400A |
Current Ranges (1 Ch.) |
75, 300A |
150, 450A |
150, 600A |
300, 1200A |
450, 2400A |
600, 2400A |
750, 3000A |
1500, 6000A |
1800, 7200A |
Voltage Ranges |
10 - 200, 10 - 400 VDC
|
Ripple |
<400mV RMS (into resistive load) |
Power Amplifier Mode |
Control Method2 |
Analog Input ±10V PK-PK amplified to ±247.5V PK-PK (low range) and ±495V PK-PK (high range) |
Latency (input-output) |
50 uS typical |
AC & DC Measurements |
Peak Voltage |
406V / 724V RMS |
Accuracy |
0.1% Reading + 0.1% F.S. (AC RMS or DC) |
Resolution |
0.005% F.S. |
Peak Current (per Ch.) |
167, 500A per channel |
Accuracy |
0.1% Reading + 0.1% F.S. (AC RMS or DC) |
Resolution |
0.005% F.S. |
Peak Power |
575V / 1050V Peak |
Accuracy (kW or kVA) |
0.1% Reading + 0.1% F.S. (AC RMS or DC) |
Resolution |
0.005% F.S. |
Add'l Measurements |
Energy (Ah, kWh, kVAh), AC Crest Factor, AC Power Factor, True Power (P), Reactive Power (Q), Waveform Capture |
Physical |
Connectors |
2 x ½”inch stud terminals per channel (Total of six) + Ground |
Cabinet Dimensions (HxWxD) |
78” x 28” x 39″ / 1980mm x 712mm x 990mm |
Cabinet Weight |
1000lbs/454kg for 50kW cabinet; 1200lbs/545kg (for 75kW and 100kW cabinet) |
Operating Temperature |
5 - 35°C (up to 95% RH non-condensing) |
1 Refer to the gain / frequency graph , 2 THD is tested based on output 480VL-L (277 VL-N) with resistive load, 3 Only 100kW cabinet can support parallel expansion; 50kW for standalone operation only. |
* The above specifications show typical configurations & subject to change. See data sheet for full product specifications. Contact NH Research, Inc. for further information. |