Voltage (V) |
Range (Auto or Manual) | 0.5V to 2000Vpk |
(12 ranges 1-2-5 sequence) | (1000V rms) |
Scaling Factors | 1.0000 to 99999 |
Computation | True rms or rectified mean |
Crest Factor | Up to 20 |
Frequency Range | DC and 0.1Hz to 200Hz |
Accuracy 23° ± 5°C 0.2V 1000Vrms | 45 - 450Hz: | ±0 .1% rdg ±0 .1% range ± 20mV |
1.Hz-200kHz: | ±0 .2% rdg ±0 .1% range 0.05%/kHz |
Effect of common | 1000Vrms 60Hz: | Less than 2OmV |
Mode Voltage | 100Vrms 100kHz: | Less than 200mV |
Maximum Input | Continuous: | 2000Vpk |
1 second: | 5000Vpk |
Input Impedance | 1 MΩ on all ranges at 15pF |
Current (A) |
Range (auto or manual) (12 ranges 1-2-5 sequences) | INT: | 0 .05A to 200Apk (30A rms) |
EXT: | 6 .25mV to 2.5Vpk (1 .5Vrms) |
Scaling Factor | INT: | 1 .0000 to 99999 |
EXT: | 8OmA/mV to 80000A/mV |
Computation | True rms or rectified mean |
Crest Factor | Up to 20 |
Frequency Range | DC and 0.1Hz to 200Hz |
Accuracy 23° ± 5°C 20mA to 30Arms | 45 - 450Hz: | ±0 .1% rdg ±0.1% range ± 1mA |
0.lHz-200kHz: | ±0.2% rdg ±0.1% range+0.05%/kHz ±1 mA |
Effect of common | 1000Vrms 60Hz: | Less than 20mA |
Mode Voltage | 100Vrms 100kHz: | Less than 200mA |
Maximum Input | Continuous: | 30Arms (must be limited by external fuses or CT's) |
Input Impedance | 1 second: | 1000Apk |
INT: | 0.0125Ω on all ranges |
EXT: | 1 MΩ on all ranges at 15pF |
Power (W) |
Ranges (auto or manual) (144 ranges corresponding to V & A) | 25mW to 400kW pk (with scaling to 100,000MW) |