Related Products
Montena MOL3000 Optical Link
- Bandwidth (±1.5dB): 80Hz - 3.5GHz
- Link gain (80Hz - 2.2GHz): 0dB ± 1.0dB
- Link gain (2.2 - 3.5GHz): 0dB ± 1.5dB
Com-Power CLCE-1032 EMI Current Probe
- Frequency Range: 9kHz - 1000MHz
- Aperture: 1.26in (32mm)
- Pulse Current: 500A
Solar 9123-1N Current Monitor Probe
- 10kHz – 500MHz
- 1.0 – 5.0 Ω above 150kHz
- Type N, Female
Pearson Electronics 110 Current Monitor Probe | 1Hz – 20MHz
- Current monitor probe
- Robust peak current capacity of 5 kA
- Frequency response reaching up to 20 MHz
Pearson Electronics 410 Current Monitor Probe
- 120 Hz – 20 MHz
- Max RMS Current: 50 A
- Max Peak Current: 5,000 A
Pearson Electronics 1423 Current Monitor
- Frequency: 1 Hz - 0.7 MHz
- Max Peak Current: 500,000 A
- Current-Time Product: 75 A·s
Pearson Electronics 3025 Current Monitor
- Frequency: 7 Hz - 4 MHz
- Peak Current: 20,000 A
- Sensitivity: 0.025 V/A
Tekbox TBCP2-750 RF Current Monitor Probe
- Frequency range: 1kHz - 1GHz
- Aperture diameter: 32mm
- Transfer impedance: 0 - 20dBΩ from 1.5 - 850MHz
Tekbox TBCP2-30K400 RF Current Monitor Probe
- Frequency range: 10Hz - 500MHz
- Aperture diameter: 32mm
- Transfer impedance: 2dBΩ with a 30kHz - 400MHz 3dB bandwidth
Tekbox TBCP5-150K400 RF Current Monitor Probe
- Frequency Range: 10Hz - 500MHz
- Application: High saturation, >200A
- Aperture Diameter: 46mm
Pearson Electronics PRD-240 Powerline Ripple Detector
- 10 Hz – 150 kHz
- 240 V AC / 270 V DC
- CS101 profile above 5 kHz
Fischer Custom Communications F-72 Current Probe
- Frequency Range: 100Hz - 100MHz
- Max Current: 350A
- Aperture Size: 67mm
Fischer Custom Communications F-33-2 Current Probe
- Frequency Range: 1kHz - 250MHz
- Aperture: 32mm
- Pulse Current: 50A
Fischer Custom Communications F-16-1 Current Probe
- Frequency Range: 100Hz - 70MHz
- Aperture: 32mm
- Pulse Current: 300A
Com-Power CLCE-438 RF Current Probe
- Frequency Range: 9kHz - 400MHz
- Aperture: 1.49in (38mm)
- Pulse Current: 800A
PMM CLCE-400 Current Monitor Probe | 10 kHz – 400 MHz
- Frequency Range: 10 kHz to 400 MHz
- Suitable for CISPR, Mil-STD-461 & DO-160
AH Systems BCP 600 Series EMI Current Probes
- Max Current: 200 - 600A
- Frequency Ranges up to 500MHz
- Aperture: 1.25" (3.2cm)/2.6" (6.6cm)
AH Systems BCP-526 Broadband Current Probe
- Frequency Range: 100kHz - 1GHz
- Max Primary Current (DC - 400 Hz): 350A
- Aperture: 1.2" (3.0cm)
AH Systems BCP-520 Broadband Current
- Frequency Range: 10kHz - 500MHz
- Max Continuous Current: 350A
- Aperture: 2.8" (71mm)
AH Systems BCP-512 Broadband Current Probe
- Frequency Range: 1 - 1000MHz
- Max Continuous Current: 200A
- Aperture: 1.2" (32mm)
AH Systems BCP-511 Broadband Current Probe
- Frequency Range: 20kHz – 100MHz
- Max Continuous Current: 350A
- Aperture: 1.2" (32mm)
AH Systems BCP-510 Broadband Current Probe
- Frequency Range: 20Hz - 1MHz
- Max Cont. Current: 100A
- Aperture: 1.2" (32mm)
Solar 7541-1 Spike Receptor Probe
- Spike receptor probe (calibrated for use with oscilloscope)
- The receptor probe is assembled with a hinged construction
- Includes a calibrating resistor mounted in the housing
Pearson Electronics 3525 Current Monitor | 5 Hz – 15 MHz
- 0.1 V/A +1/-0% sensitivity
- 50 Ω output resistance
- Maximum peak current of 5000 A
Pearson Electronics 101 Current Monitor Probe | 0.25Hz - 4MHz