Related Products
Schneider Electric S33595 Circuit Breaker Full Function Test Kit
- Current Injection: 0.02 – 2.3A DC
- Voltage Output: 0.031 – 21.5Vrms
- Trip Time: 0 – 3000s (±5 mS)
Cutler Hammer Eaton MTK2000
- Max Test Current: Up to 1200A
- Protection Tests: LT, ST, Inst, GF
- Compatible w/ Digitrip MDS-520 / -1150
Siemens PTS-4 Portable Test Set
- Max Output Current: 0 – 10A continuous
- Input Power: 120V, 50/60Hz, 15A max
- Max Output Voltage: 220V
Siemens TS-31 Secondary Injection Test Set
Cutler Hammer 140D481G03 DS Breaker Test Kit
- Short delay
- Ground test
- Circuit selector
Cutler Hammer 7801C57 OPTIMizer Programmer and Trip Test
Cutler Hammer 70C1056G54 Circuit Breaker Test Set
GE TVRMS2 Digital Test Kit
- Operation from 120 Vac or six D-cell batteries.
- Trip Unit testing without de-energizing the breaker or removing the Trip Unit from the breaker.
- Verification of switch settings on Power+, RMS-9, and Epic Trip Units.
Cutler Hammer Digitrip OPTIM Trip Unit System
- Programmable protection and coordination
- Trip early warnings
- System diagnostics
Madison Testing DMR5I1 Multifunction Trip Unit Adapter
- Easy connect to any configuration
- Budget-friendly solution for testing aftermarket Digitrip RMS retrofitted trip units
- Offers 32 VDC and 120 VAC power source for OPTIM 750 & 1150, and GO3 base unit
Siemens WLTS Secondary Current Injection Test Set
Schneider Electric / Square D S33594 Circuit Breaker Handheld Test Kit
- Solution for testing and troubleshooting electrical systems
- Works with micrologic trip units and compact NS circuit breakers
- User-friendly interface
Cutler Hammer 140D481G02R DS Breaker Test Kit
- Accommodate the lower power requirements of microprocessor
- Permits checking of all Trip Unit phase input circuits
- Pickup value accuracy ±10%
Cutler Hammer 1287C56G02 Secondary Injection Test Kit
Cutler Hammer 1232C50G10 Secondary Injection Test Kit
Cutler Hammer 1232C50G05 Secondary Injection Test Kit
ABB BTSB Benchtop Trip Simulator for Breakers
ABB 504 Power Shield Test Set
Eaton Cutler Hammer MTST230V Functional Test Kit
- Compatible with Digitrip 520, 520M, 520MC, and 1150 series
- 120 V and 240 V handheld testing
Schneider Electric / Square D UTA Test Set for PowerPack H-, J- and L-Frame Circuit Breakers
General Electric TVTS1 Secondary Injection Test Set
- TP4VT
- TP9VT
- T4VT
Doble TDR900 Circuit Breaker Test System
- Testing Range and Precision: It can test circuit breakers by recording timing for up to four breaks per phase, with motion measurements, providing high-resolution results (100 µs).
- Functional Commands: The TDR900 manages various breaker operations such as Trip, Close, Reclose, and self-diagnostics, enhancing its utility for detailed functional tests.
- High Accuracy Motion Recording: This feature allows for the detection of mechanical problems within the breaker mechanism, ensuring thorough preventative maintenance.
GE TAK-TS2 Secondary Injection Test Set for SST/ECS Trips
GE TAK-TS1 Test Set
Carriere STS100 Secondary Injection Relay Tester
- Provides the following output ranges 0-2 Amps continuous 0-8 Amps for 24 seconds on, 120 Seconds off 0-10 Amps for 12 seconds on, 60 seconds off 0-12 Amps for 0.6 seconds on, 3 seconds
- 0-2 Amps continuous
- 0-8 Amps for 24 seconds on, 120 Seconds off