Ophir OTG117 Induced Lightning System

Rent Ophir OTG117 Induced Lightning System
Enlarge Image
Ophir OTG117
Request Quote Print Page
Datasheet
The Ophir OTG117 Induced Lightning System is a two part system designed to cover the latest edition of Mil-Std-461G, CS117 consisting of OTG117.1 Multiple Stroke Generator covering Waveform 1-2 and 4-5 and OTG117.2 Multiple Stroke/Burst Generator covering Waveform 3 and 4. Cables and Probes/cores included with system.

The OTG117.1 generator is capable of producing Current Waveform 1, Voltage Waveform 2 or Voltage Waveform 4, and Current Waveform 5A all in the Multiple Stroke format. Single event triggering is also available for engineering testing and level setting. It can produce these Waveforms at both the Internal and External Equipment Levels (see Table 1). The OTG117.2 generator is capable of producing Waveform 3 (1MHz & 10MHz) Multiple Stroke and Multiple Burst, as well as Waveform 6 Multiple Burst. Single event triggering is also available for engineering testing and level setting. It can produce these Waveforms at both the Internal and External Equipment Levels (see Table 2).
 
Ophir OTG117 Specs
Table 1
Multiple Stroke
Applicability Test Description Internal Equipment Levels** External Equipment Levels**
All equipment
installations
Waveform 2 (WF2)/
Waveform 1 (WF1)
First Stroke
VL = 300 V (WF2)
IT = 600 A (WF1)
IT = 60 A*
Subsequent Strokes
VL = 150 V (WF2)
IT = 150 A (WF1)
IT = 30 A*
First Stroke
VL = 750 V (WF2)
IT = 1500 A (WF1)
IT = 150 A*
Subsequent Strokes
VL = 375 V (WF2)
IT = 375 A (WF1)
IT = 75 A*
Equipment installations routed in areas with
composite skin/structure.
Waveform 4 (WF4)/
Waveform 5A (WF5A)
First Stroke
VL = 300 V (WF4)
IT = 1000 A (WF5A)
IT = 300 A*
Subsequent Strokes
VL = 75 V (WF4)
IT = 200 A (WF5A)
IT = 150 A*
First Stroke
VL = 750 V (WF4)
IT = 2000 A (WF5A)
IT = 750 A*
Subsequent Strokes
VL = 187.5 V (WF4)
IT = 400 A (WF5A)
IT = 375 A*
 
Table 2
Multiple Stroke
Applicability Test Description Internal Equipment Levels External Equipment Levels
All equipment installations Waveform 3 (WF3) – 1 MHz and 10 MHz First Stroke
VT = 600 V (WF3)
IL = 120 A (WF3)
IL = 24 A*
Subsequent Strokes
VT = 300 V (WF3)
IL = 60 A (WF3)
IL = 12 A*
First Stroke
VT = 1500 V (WF3)
IL = 300 A (WF3)
IL = 60 A*
Subsequent Strokes
VT = 750 V (WF3)
IL = 150 A (WF3)
IL = 30 A*
Multiple Burst
Applicability Test Description Internal Equipment Levels External Equipment Levels
All equipment installations Waveform 3 (WF3) – 1 MHz and 10 MHz VT = 360 V (WF3)
IL = 6 A (WF3)
VT = 900 V (WF3)
IL = 15 A (WF3)
Equipment installations that
utilize short, low impedance cable bundle installations.
Waveform 6 (WF6) VL = 600 V (WF6)
IT = 30 A (WF6)
VL = 1500 V (WF6)
IT = 75 A (WF6)