Programming |
Read-Back / Monitoring |
|
|
Accuracy |
Resolution |
Accuracy |
Resolution |
|
Front Panel Display |
SGI (40-1000V) +/- 0.1% of voltage at full scale
SGI (40-1000V) +/- 0.4% of current at full scale |
SGI: 4.0 digits |
SGI, Voltage: +/- 0.1% of full scale
SGI, Current: +/- 0.4% of full scale |
SGI: 4.0 digits |
Knob Control & Display Read-Back |
SGI (10-30V) 0.1% of set point +0.1% of voltage rating
SGI (10-30V) 0.1% of set point +0.4% of current rating |
SGI (10-30V) 0.1% of actual +0.15% voltage rating |
Remote Analog Interface |
Voltage +/-0.25% of full scale
Current (40-1000V) 0.8% of full scale , (10-30V) 1.0% of full scale |
NA |
(40-1000V) +/-1.0% of full scale
(10-30V) +/-0.5% of full scale |
NA |
25-pin D-sub connector (0~5 V or 0~10 V) |
Remote Digital Interface |
Voltage: +/- 0.1% of full scale
Current: +/- 0.4% of full scale |
+/-0.002% of full scale |
Voltage: +/- 0.1% of full scale
Current: +/- 0.4% of full scale |
+/-0.002% of full scale |
RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet (see Options) |
OVP |
+/- 1% of full scale |
+/-0.002% of full scale |
|
|
Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs |
User I/O |
Disconnect & Polarity-reversal relay control (Only available with Ethernet Option ) |
Digital 10-pin Molex type connector |
Software |
IVI & CVI drivers available under SUPPORT |