IEC
IEC 61000-4-28: Testing and measurement techniques - Variation of power frequency, immunity test
Compliance Standards | EMC, Safety & Environmental Testing | ATEC
> IEC Standards
> IEC 61000-4-28 Testing
IEC 61000-4-28 Standard Overview
IEC 61000-4-28 establishes a reference for evaluating the immunity of electric and electronic equipment when subjected to variations of the power frequency. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial networks.
This standard applies to electric and/or electronic equipment connected to 50 Hz or 60 Hz distributed network with rated line current up to 16 A per phase.
It does not apply to electric and/or electronic equipment connected to AC 400 Hz distribution networks. Tests concerning these networks will be covered by other IEC standards.
In general, electrical and electronic equipment is not susceptible to minor variations of the power frequency. Testing according to this standard should be limited to products that are assessed to be susceptible to power frequency variations by design, environment or failure consequences.
The immunity test levels required for a specific electromagnetic environment together with the performance criteria are indicated in the product, product family or generic standards as applicable.
This standard applies to electric and/or electronic equipment connected to 50 Hz or 60 Hz distributed network with rated line current up to 16 A per phase.
It does not apply to electric and/or electronic equipment connected to AC 400 Hz distribution networks. Tests concerning these networks will be covered by other IEC standards.
In general, electrical and electronic equipment is not susceptible to minor variations of the power frequency. Testing according to this standard should be limited to products that are assessed to be susceptible to power frequency variations by design, environment or failure consequences.
The immunity test levels required for a specific electromagnetic environment together with the performance criteria are indicated in the product, product family or generic standards as applicable.
Products Used in Testing
Pacific Power 3150AFX AC & DC Programmable Power Source
- Frequency: DC, 15 – 1,200 Hz
- Accuracy: ± 0.01%
- 125 Arms / 62.5 ADC
EM Test Netwave Series, Single Phase AC/DC Power Source
- Wide Power Bandwidth; DC - 5kHz
- Output Power up to 7,500VA AC and 9,000W DC
- Output Voltage max. 360V AC and +/- 500V DC
Teseq ProfLine 2100 Harmonics and Flicker Measuring System
Teseq Profline 2105 | 1 ph, 5 KVA
- 5 kVA output power
- Immunity test system that is simple to upgrade, pc-based
- Accessible control interface
Pacific Power 3210AGX | AC & DC Load/Power Supply | 21 kVA
- Power: 21kW/kVA
- Voltage: 350VAC, 500VDC
- Current: 21ADC
Pacific Power 3550AZX Regenerative AC & DC Power Source
- Power: 55kVA/kW
- 0-240 Vac L-N / 0-415 Vac L-L
- Current: 225ARMS, 150ADC
California Instruments Tahoe | TA0045A1 Power Supply | 45 kVA
- Output: 45kVA, 0-166/333Vrms, 1/3ph
- Frequency Range: 16Hz - 905Hz
- Input Power: 208/600VAC, 3ph
California Instruments Sequoia SQ0045 Regenerative AC Grid Simulator
- Power: 45kVA/kW
- Voltage: 333VRMS, 440VDC
- Current: 125/62.5ARMS, 85/42.5ADC
California Instruments 5001iX AC Power Source
- Output: 5kVA, 0-150/300V, 1ph
- Frequency Range: 16 - 1000Hz
- Input Power: 208/240VAC, 1ph
California Instruments 1251RP Programmable AC Power Source
- Output: 1.25kVA, 0-135/270V, 1ph
- Frequency Range: 16 - 500Hz
- Input Power: 85-265Vrms, 1ph
Related IEC Standards
Explore All Standards
IEC 60050-444 International Electrotechnical Vocabulary Part 444: Elementary Relays
IEC 60255: Electrical Relays
IEC 60270: Partial Discharge Measurements
IEC 60533: EMC Testing of Ships with Metallic Hulls
IEC 60601-1-2: Medical Electrical Equipment - Collateral standard: Electromagnetic compatibility...
IEC 61000-3-2: Limits - Limits for Harmonic Current Emissions (equipment input current up to and...
IEC 61000-3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public...
IEC 61000-3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker...
IEC 61000-3-12: Limits for harmonic currents produced by equipment connected to public...
IEC 61000-3-13: Electromagnetic compatibility (EMC) Limits - Assessment of emission limits for...
IEC 61000-4-2: Electrostatic Discharge Immunity Test
IEC 61000-4-3: Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4: Electrical Fast Transient (EFT) / EMC Burst Immunity Test Standard
IEC 61000-4-5: Testing and Measurement techniques - Surge Immunity Test
IEC 61000-4-6: Immunity to Conducted Disturbances, Induced by Radio Frequency Fields
IEC 61000-4-7: General Guide on Harmonics and Interharmonics Measurements and Instrumentation
IEC 61000-4-8 Electromagnetic Compatibility (EMC) - Part 4-8: Testing and Measurement Techniques...
IEC 61000-4-9 Electromagnetic Compatibility (EMC) - Part 4-9: Testing and Measurement Techniques...
IEC 61000-4-10: Testing and Measurement Techniques Damped Oscillatory Magnetic Field Immunity Test
IEC 61000-4-11: Testing and Measurement Techniques - Voltage Dips, Short Interruptions and...
IEC 61000-4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-13: Testing and measurement techniques - Harmonics and interharmonics including mains...
IEC 61000-4-14: Testing and measurement techniques - Voltage fluctuation immunity test
IEC 61000-4-15: Testing and Measurement Techniques - Flickermeter. Functional and Design...
IEC 61000-4-16: Testing and Measurement Techniques – Test for Immunity to Conducted, Common Mode...
IEC 61000-4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
IEC 61000-4-18: Testing and measurement techniques – Damped oscillatory wave immunity test
IEC 61000-4-19: Test for Immunity to Conducted, Differential Mode Disturbances and Signaling
IEC 61000-4-20 Electromagnetic compatibility (EMC) – Part 4-20: Testing and measurement techniques...
IEC 61000-4-21 Electromagnetic compatibility (EMC) Part 4-21: Testing and measurement techniques...
IEC 61000-4-27: Unbalance, immunity test
IEC 61000-4-29 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement...
IEC 61000-4-30: Testing and Measurement Techniques - Power Quality Measurement Methods.
IEC 61000-4-31: Testing and measurement techniques - AC mains ports broadband conducted disturbance
IEC 61000-4-34: Testing and Measurement Techniques - Voltage Dips, Short Interruptions...
IEC 61000-4-39:2017: Electromagnetic Compatibility Immunity Requirements
IEC 61000-6-2: Immunity Testing of Industrial Equipment
IEC 61000-6-4: Emission standard for industrial environments
IEC 61000-6-5: Immunity for Power Station and Substation Environments
IEC 61010-1: Safety of Measuring, Control and Laboratory Equipment
IEC 61326: EMC Testing of Laboratory Equipment
IEC 61340-3-1: Methods for Replication of Electrostatic Effects - Human Body Model (HBM)...
IEC 61340-3-2: Methods for Replication of Electrostatic Effects – Machine Model (MM)...
IEC 61672-1: Electroacoustics – Sound level meters – Part 1: Specifications
IEC 61672-2: Electroacoustics – Sound level meters – Part 2: Pattern evaluation tests
IEC 61672-3: Electroacoustics – Sound level meters – Part 3: Periodic tests
IEC 61850: Communication Networks and Systems in Substations
IEC 62037: Passive RF and Microwave Devices, Intermodulation Level Measurement
IEC 62233: Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human
IEC 62619: Safety Requirements for Secondary Lithium Cells and Batteries, for Use in Industrial Applications
IEC 62764-1: Low-Frequency Magnetic Fields