Related Products
Megger Torkel 950 Battery Load Unit
- Display range: 0.0 to 2999.0 A
- Basic inaccuracy: ±(0.5% of reading +0.1 A)
- Resolution: 0.1 A
Megger Torkel 840 DC Battery Load Tester
- "In Service" batteries can be tested
- Load currents in the test parameters are included as the unit adjusts
- Adjustable alarm and shutdown points to prevent excessive discharge
Eagle Eye LB-480-300-CC DC Load Bank
- Rated Voltage: 480 VDC
- Current Capacity: 300 A
- Power Output: 144 kW
Megger Torkel 860 Battery Bank Load Tester
- Batteries can be tested "in service"
- Unit adjusts to include load currents in the test parameters
- User adjustable alarm and shutdown points to avoid excessive discharge
Eagle Eye SLB-24/48-300/600 DC Load Bank
- Safely monitor live tests remotely with wireless communication to the SLB load bank
- DataView software includes live monitoring, data recording, and report exporting to Microsoft Excel
- Discharge auto-shutdown for time duration, total string voltage, capacity, and individual cell voltage
Cannon Load Banks L-48-500 Load Bank 48 VDC, 500 A
- Load Steps: 100 A, 100 A, 100 A, and 100 A fixed steps, 0 - 100 A adjustable step
- Plug test pins for connecting test leads
- Meters: 0 -75 V voltmeter, 0 - 500 A ammeter
Aviation DCLB-28 28.5 VDC Load Bank | 300-1500 Amps
- 300 A continuous load
- 1500 A decreasing load
- Timer bypass switch
Megger TXL 870 Extra Load Unit
- Use with Torkel Test Systems
- 112A @ 140V | 56A @ 280V
- 100 – 240V AC, 50 / 60Hz
Megger TXL 850 Extra Load Unit
- 300A / 16.4kW / 56V
- Internal Resistance: 0.184 Ω, 0.275 Ω, 0.55 Ω
- Operating Temp: 0°C ... +40°C
Megger TXL Extra Load Unit Series
- Up to 300A current & 280V DC voltage
- Power Rating: 8.3kW - 16.4kW
- Three-Position Internal Resistance
Megger TORKEL 900 Battery Load Unit
- Batteries can be tested in service
- Dynamic discharge technology – full power at all voltages
- Safety in all details, e.g. detection of blocked airflow
Megger Torkel 820 12, 24, 48 Volt DC Battery Load Unit
- External measurement input used to measure current in an external path by means of a clamp-on ammeter or a current shunt.
- Alarm output equipped with a relay contact for triggering an external alarm device.
- Start/Stop input used for starting and stopping discharging from an external device. Galvanically isolated.
Eagle Eye LB-Series SMART DC Load Banks
- LED display for voltage, current, and test duration
- Three test conditions for discharge auto-stop: Test Time, End Voltage,
- Exceeded Capacity, and Cell Voltage*