Related Products
Emerson AMS Trex
- HART and Fieldbus communication
- Built‑in loop power up to 22.5 mA
- Automatic documentation and audit trail
Emerson AMS Trex 2 Device Communicator
- HART and Fieldbus Communication
- Supports Loop Diagnostics Functionality
- Identifies Valve Problems
Emerson HART Communicator 475
- HART 5–7 and Fieldbus
- 20 hr battery
- 32 MB plus 1 GB
Druck DPI 802 Pressure Calibrator
- Pressure: ±0.36 psi to 10,000 psi
- Accuracy: 0.1% FS to 0.05% FS
- Loop calibration: 0–55 mA with 24 V supply
Druck DPI610E Pressure Calibrator Series
- Range: Vacuum to 1000 bar
- Accuracy: 0.025% FS
- Loop power: 24 V mA
Druck DPI 800 Pressure Indicator
- Pressure: ±0.36 psi to 10,000 psi
- Accuracy: 0.1% FS to 0.05% FS
- Stability: ≤0.02% reading per year
Druck DPI 611 Hand-held Pressure Calibrator Series
- Range: −14.5 to 300 psi
- Accuracy: ±0.0185% FS
- I/O: pressure + mA/V
Druck DPI 610 Series Portable Hydraulic Pressure Calibrator
- Ranges -14.7 to 10,000 psi
- Accuracy from 0.025% full scale (FS)
- Pressure + mA/V testing
Additel 780 Pressure Calibrator
- Pressure range: Vacuum to 3,000 psi
- Accuracy: 0.02% FS or 0.01% of reading
- Control stability: 0.003% FS
Additel 760 Automatic Handheld Pressure Calibrator
- Range: ±30 inH₂O to 300 psi
- Accuracy: 0.02% FS
- Stability: <0.005% FS
Fluke 744 Documenting Process Calibrator (HART)
- Accuracy: ±0.01–0.025%
- Built‑in HART communication
- Simultaneous source & measure
Fluke 743B Documenting Process Calibrator
- High‑accuracy 4–20 mA calibration
- Wide RTD and thermocouple range
- Built‑in logging and documentation
Fluke 729 Series Automatic Pressure Calibrator
- 30G: −12.0000 - 30.0000 psi
- 150G: −12.000 - 150.000 psi
- 300G: −12.000 - 300.000 psi
Fluke 7250LP Low Pressure Calibrator
- 10 inH2O and 30 inH2O
- 20 inH2O and 60 inH2O
- 35 inH2O and 100 inH2O
Fluke 719Pro Series Electric Pressure Calibrator
- 30G: −12 - 30 psi
- 150G: −12 - 150 psi
- 300G: −12 - 300 psi
Fluke 4322 Automated Pressure Calibration System
- Range: 0.5 psi to 10,000 psi
- Accuracy: ±0.1% of reading
- Control: automated pressure generation
Fluke 3130 Portable Pneumatic Pressure Calibrator
- Pressure range: vacuum to 2 MPa (300 psi)
- Accuracy: ±0.025% of reading ±0.01% FS
- Electrical I/O: 4–20 mA, 0–30 V dc, 24 V loop power
King Nutronics 3112 Pressure Calibration Test System
- Range: 0–100 psig (low), 0–2,000 psig (high)
- Accuracy: ±0.5% of full scale
- Internal supply: 7.1 SCF nitrogen @ 2,250 psig
Additel 227EX HART Communicator
- Pressure accuracy: 0.002% FS
- Electrical accuracy: ±0.005% RD + 0.005% FS
- Intrinsically safe
Fluke 2271A
- Pressure: −100 kPa to 20 MPa
- Accuracy: 0.02% of full scale
- Control: 0.001% range precision, 10:1 turndown
Fluke 154 Multifunction HART Communicator
- HART 4.0 to 7.0
- Bluetooth 275 ft
- 19 hr battery
Additel 761A Automated Pressure Calibrator Series
- Pressure range: Up to 1,000 psi
- Accuracy: Up to 0.01% FS
- Stability: 0.003% FS
Druck DPI 612 Pressure Calibrator
- −95% vacuum to 1000 bar range
- Interchangeable modules, 0.005% FS accuracy
- Integrated pressure & electrical measurement