Related Products
Emerson AMS Trex
- HART and Fieldbus communication
- Built‑in loop power up to 22.5 mA
- Automatic documentation and audit trail
Fluke 754 Documenting Process Calibrator-HART
- Accuracy to ±0.01% of reading
- Loop Power: 26 V DC, max 25 mA
- Voltage Measure: 0–300 V AC/DC
Fluke 9142 Field Metrology Well
- Temperature range: –25 °C to 150 °C
- Stability: ±0.01 °C over full range
- Display accuracy: ±0.2 °C over full range
Fluke 9144 Field Metrology Well
- Temperature range: 50 °C to 660 °C
- Stability: ±0.03 °C at 50 °C to ±0.05 °C at 660 °C
- Accuracy: ±0.35 °C to ±0.5 °C over range
Fluke 9009 Dual-Block Thermometer Calibrator
- Temperature range: −15 °C to 350 °C
- Accuracy: ±0.6 °C hot block; ±0.2 °C cold block
- Stability: ±0.05 °C
Fluke 6102 / 7102 Micro-Bath Thermometer Calibrator
- Stability: ±0.015 °C to ±0.05 °C
- Accuracy: ±0.25 °C
- Range: 35 °C to 200 °C / −5 °C to 125 °C / −30 °C to 125 °C
Omega FOB104 Fiber Optic Thermometer
- 0 - 10V
- 4 - 20mA (optional)
- 4 channels
Fluke 789 Loop Calibration Multimeter
- 24 V Loop power supply
- Accuracy: ±0.05% of span
- Output / Source Range: 0–20 mA
Additel 780 Pressure Calibrator
- Pressure range: Vacuum to 3,000 psi
- Accuracy: 0.02% FS or 0.01% of reading
- Control stability: 0.003% FS
Additel 760 Automatic Handheld Pressure Calibrator
- Range: ±30 inH₂O to 300 psi
- Accuracy: 0.02% FS
- Stability: <0.005% FS
Fluke 7526A Precision Process Calibrator
- Electrical accuracy: ±30 ppm (V), ±50 ppm (mA)
- Temperature accuracy: ±0.02 °C (RTD), ±0.09 °C (TC)
- Pressure accuracy: ±0.008 % of reading (with modules)
Fluke 744 Documenting Process Calibrator (HART)
- Accuracy: ±0.01–0.025%
- Built‑in HART communication
- Simultaneous source & measure
Fluke 743B Documenting Process Calibrator
- High‑accuracy 4–20 mA calibration
- Wide RTD and thermocouple range
- Built‑in logging and documentation
Fluke 741B Documenting Process Calibrator
- ±0.025 % DC voltage accuracy
- ±0.01 % DC current accuracy
- Temperature range: −250 °C - 2316 °C
Fluke 729 Series Automatic Pressure Calibrator
- 30G: −12.0000 - 30.0000 psi
- 150G: −12.000 - 150.000 psi
- 300G: −12.000 - 300.000 psi
Fluke 726 Precision Multifunction Process Calibrator
- ±0.01% measurement and source accuracy
- 24 V DC loop supply for transmitter testing
- Dual channels for simultaneous measure and source
Fluke 7250LP Low Pressure Calibrator
- 10 inH2O and 30 inH2O
- 20 inH2O and 60 inH2O
- 35 inH2O and 100 inH2O
Fluke 725 Multifunction Process Calibrator
- Measure/Source: 0–24 mA
- Accuracy: ±0.02% of reading + 2 LSD
- Maximum load: 1000 Ω
Fluke 724 Temperature Calibrator
- TC and RTD support
- 24 V loop power
- –200 °C to 800 °C RTDs
Fluke 719Pro Series Electric Pressure Calibrator
- 30G: −12 - 30 psi
- 150G: −12 - 150 psi
- 300G: −12 - 300 psi
Fluke Calibration 714B Thermocouple/Temperature Calibrator
- Temperature range: –250 °C to 2316 °C
- Sensor support: 17 thermocouple types
- mA measurement: 0 to 24 mA
Fluke 712B RTD Temperature Calibrator
- RTD range: –200 °C to 800 °C
- RTD accuracy: as low as ±0.2 °C
- mA measurement: 0 to 24 mA
Fluke 710 mA Loop Valve Tester
- Ranges: 0 - 24 mA | 0 - 30 V DC
- Resolution: 1 µA on mA | 1 mV on V
- Accuracy: 0.01% ±2 counts
Fluke 6109A / 7109A
- Temperature range: −25 °C to 250 °C
- Display accuracy: ±0.1 °C
- Uniformity: ≤0.04 °C
Fluke 4322 Automated Pressure Calibration System
- Range: 0.5 psi to 10,000 psi
- Accuracy: ±0.1% of reading
- Control: automated pressure generation