Frequency Ranges |
TX RANGE |
869-894 MHz |
RX RANGE (PIM) |
824-849 MHz |
System |
Measurement method |
Reverse (reflected) PIM, 3rd, 5th, 7th and 9th order |
Residual PIM |
< -115dBm/-158dBc max (<-125dBm/-168dBc typ.) |
User interface ports |
2x USB, x1 LAN 1x RF output (7-16 DIN female) |
Display |
8.4in (213mm) touch screen display |
Transmitter |
Frequency increment |
50 kHz |
Frequency accuracy |
± 5ppm (max), aging ± 1ppm (max) after first year |
Power per tone (adjustable) |
2x 2 to 20W (+33 to +43dBm) |
Power accuracy (per tone) |
± 0.5dB (max) |
Receiver |
Measurement noise floor |
< -128dBm |
Measurement range |
-50dBm to -128dBm |
Electrical |
Mains power |
115-230V, 50/60Hz AC |
Power consumption |
650W |
Mechanical |
Dimensions |
19 x 18 x 12in (500 x 457 x 305mm) |
Weight |
< 50lbs (22.7kg) |
Cooling |
Forced air |
Environmental |
Operating temperature range |
-10°C to +40°C |
Storage temperature range |
-20°C to +60°C |
Ingress protection (IP) |
IP20 (with lid open) IP21 (with lid closed) |
Relative humidity |
5% to 95% RH non-condensing |
Mechanical shock |
40G shock rating |