Related Products
Teseq NSG 4070B Conducted Immunity Test System
- Amp Range: 150kHz - 230MHz (80W)
- Sig Gen Range: 9kHz - 1GHz
- 3 Power Meter Ports
EM Test CWS 500N1 Continuous Wave Simulator
- Signal generator: 9kHz to 1GHz
- Amplitude modulation: 1Hz to 3kHz (0% to 95%)
- Pulse modulation: 1Hz - 1kHz (10% to 90%)
Teseq NSG 4060 Low Frequency Immunity Test System
- Signal generator and integrated power amplifier 15 Hz to 150 kHz
- Meets IEC / EN 61000-4-16 in combination with the Extension Unit
- Meets IEC / EN 61000-4-19 and other standards
AE Techron DSR 100-200 | Pulse 2B and 4
- Frequency Range: DC - 250 kHz
- Output Current: 0A - 200A (Cont.)
- DO 160G, ISO 7637-2, MIL STD 461F
AE Techron 3110 Standards Waveform Generator
- DC-20kHz (DAC), DC-300kHz (Sine)
- 120VAC, 1.0VA service, 1Ø
- IEC 6100-4-16, ISO 7637, ISO 16750-2
Schloder CDG7000-75-10
- Amp Range: 10kHz - 250/400MHz (25/75W)
- Sig Gen Range: 9kHz - 1.2GHz
- 3 Ports
AE Techron HVR 2000RG-200 High Voltage Ripple Generator
- Up to 2000VDC
- DC - 200kHz
- Up to 50Vp
AE Techron 7234 Audio Power Amplifier
- Frequency Range: DC - 1MHz
- Power: 900W RMS
- Slew rate: 100V/µs
Amplifier Research CI00402 RF Conducted Immunity System
- Amp Range: 10kHz - 400MHz at 100V
- Sig Gen Range: 9kHz - 1.5GHz
- 2 Power Meter Ports
AE Techron 7228 Linear Power Amplifier
- Frequency Range: DC – 1MHz
- AC Power: 1000W RMS
- Slew rate: 100 V/μs
EMC Partner IMU C-SHORT Common Mode Short Duration Testing Extension
- IEC 61000-4-16 Standard
- Testing capabilities that find conducted immunity
- Common mode extension
Fischer Custom Communications F-120-9A
- Frequency: 10kHz - 230MHz
- Power: 100W, Loss: <8dB
- Inner Diameter: 1.57in (40mm)
PMM EMCL-35 10 kHz - 1 GHz EM Injection Clamp | 35mm Aperture
- Frequency Range: 10kHz - 1GHz
- Power: 100W, Typ. Coupling Factor: -3dB
- Inner Diameter: 1.38in (35mm)
Teseq NSG 4070C-80 Test System for Conducted and Radiated Immunity
- Amp Range: 150kHz - 230MHz at 80W
- Sig Gen Range: 4kHz – 1GHz
- 3 Power Meter Ports
AE Techron 8302 RF Amplifier
- Frequency Range: DC - 50kHz
- Power: 2kW
- Slew Rate: 65V/µs
Teseq (Schaffner) KEMA 801A Decoupling Clamp
- Decoupling Network/ RF attenuation clamp
- As specified in IEC/EN 61000-4-6
- Very efficient coupling
Fischer Custom Communications F-130A Bulk Current Injector Probe
- Frequency Range: 1MHz - 700MHz
- Power: 50W (CW), Loss: ≤6dB
- Inner Diameter: 1.26in (32mm)
PMM Cond-IS/10 Conducted Immunity System
- Generator 3010, 9 kHz – 1 GHz, -107 to +10 dBm
- Amplifier 6000N, 9 kHz – 230 MHz, 10/15 W
- ATT-25W, 6 dB Attenuator, 25 W max
Solar 9719-1N Injection Probe
- Frequency Range: 10kHz - 350MHz
- Power: 200W
- Inner Diameter: 1.5in (38mm)
Fischer Custom Communications FCC-BCICF-2
- Bulk current injection probe fixture
- Matched with the F-140 bulk current injection probe
- Easy-to-use design
Com-Power CLA-150 Absorbing Clamp 30 MHz - 1 GHz
- Frequency Range: 30 - 1000 MHz
- Impedance: 50 Ohm
- Connector Type: BNC (f)
Montena MOL3000 Optical Link 80 Hz to 3.5 GHz
Fischer Custom Communications F-140 Bulk Current Injection Probe
- Frequency Range: 100kHz - 1GHz
- Power: 100W
- Inner Diameter: 400mm
AE Techron T1000 Magnetic-Field Susceptibility Transformer
- Up to 100ARMS secondary current.
- Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5 Section 7.2.2.
- Circuit breaker protected from over-current.
AE Techron T3700 Electric-Field Susceptibility Transformer
- Up to 3,700 volts, 11,000 V/m.
- Meets or exceeds voltage requirements of DO 160 Section 19 and Boeing D6-16050-5 Section 7.2.
- Robust design; withstand tested to 5,000VRMS.