Phases mode: | 1 | 3 |
OUTPUT RATINGS |
Power per phase | 4500 VA | 1500 VA |
Voltage Ranges (rms) | 0-150 V/0-300 V | 0-150 V/0-300 V |
Maximum rms Current per phase |
low range: | 30 A | 10 A |
high range: | 15 A | 5 A |
Maximum Repetitive Current per phase |
low range: | 120 A | 40 A |
high range: | 60 A | 20 A |
Crest Factor (Current): | 4.0 |
Output Frequency Range: | 45 Hz - 5 kHz |
Constant Voltage Ripple and Noise: | -60 dB (20 kHz - 10 MHz) |
Load Regulation: | 0.5% |
Line Regulation: | 0.1% |
Maximum Total Harmonic Distortion: | 1% (45 Hz - 1 kHz), 1% + 1%/kHz (>1 kHz - 5 kHz) |
PROGRAMMING ACCURACY (@ 25°C ±5°C) |
Voltage (rms): | 0.15% + 0.3 V (45 - 100 Hz), 0.5% + 0.3 V (>100-500 Hz), 1% + 0.3 V (>500 - 5 kHz) |
Frequency: | 0.01% + 0.01 Hz |
Phase: | 0.1°(45-100 Hz), 1° (>100-1000 Hz), 1° + 1°/kHz (>1 kHz - 5 kHz) |
MEASUREMENT ACCURACY (@ 25°C ±5°C) |
Phases: | 3 |
rms Voltage: | 0.05% + 250 mV |
rms Current: | 0.1% + 25 mA |
Frequency: | 0.01% + 0.01 Hz |
Power (VA): | 0.15% + 3 VA |
Power (Watts): | 0.15% + 3 W |
Power Factor: | 0.01 |
AC Input Voltage Range (Vac): | 180-254 Vac (3 Phase), 360-440 Vac (3 Phase) |
AC Input Frequency: | 47-63 Hz |