The Megger Pinpointer model MPP2000 is engineered for precise and rapid fault detection in underground cable networks. The MPP2000 features user-friendly menus that provide advanced flexibility for experienced users. Encased in a lightweight, ergonomic, and rugged IP54-rated housing, the MPP2000 can be carried hands-free with its adjustable neck strap. Compatible with any manufacturer's surge generator, the MPP2000 detects acoustic and electromagnetic fields generated by the flashover at the fault point, using a lightweight ground microphone equipped with a shield to minimize wind noise.
Features
- Universal pinpoint fault location system
- Ergonomic, rugged, weather resistant case
- Electromagnetic, acoustic and time delay fault location methods
- Displays magnetic and acoustic signal levels
- Displays relative distance and direction to the fault
- Large backlit LCD
- Background interference suppression using selectable filters
Specifications
Range |
0 to 99.9 ms |
Resolution |
0.1 ms |
Outputs |
Loudspeaker
1 x jack for headphones |
Volume |
Adjustable for both headphone and loudspeaker |
Acoustic Gain |
Manual |
Electromagnetic Gain |
Manual |
Noise Canceling Acoustic Filters |
Digital: (3) HPF, (1) BPF, none |
Acoustic Bands |
120Hz to 1.8kHz |
Amplification Acoustic Channel |
>0 to 100 dB |
Magnetic Channel |
> 0 to 100 dB |
Display Range |
00.0 ms to 99.9 msec |
Overflow Display |
”OVFL” for distance values > 100 ms |
Frequency Range |
120 Hz to 1.8 kHz (acoustic) |
Display |
Large, easy-to-read 3.5” color LCD with backlight |
Power |
8 standard alkaline or replaceable lithium AA cell batteries |
Battery Life |
Alkaline, 24hours continuous : Lithium, 30hours continuous : >150hours intermittent (approx.) |
Temperature Range |
Operating: -4deg;F to 122°F (-20°C to 50°C)
Storage: -4°F to 149°F (-20°C to 65°C) |
Environmental |
Rated to IP54 |
Humidity |
95% non-condensing |
Dimensions |
8 L x 6.5 W x 3.25 H in. (203 L x 165 W x 83 H mm) |
Weight |
2.15 lb (.98 kg) |