Output voltage | 0.01~2.00kV ±10% with 50Ω Load (±0.04kV for <0.1kV) |
Polarity | Positive or negative |
Square wave |
Pulse width | 50ns, 100ns, 200ns, 250ns, 400ns and any combination thereof, maximum width 1μs , or 10ns±3ns (the shortest connection) |
Rise time | < 1 ns |
Output impedance | 50Ω system (53.5Ω) |
Pulse repetition mode |
PHASE | 50 or 60Hz, Injection phase angle 0~359°(Synchronized with L1, L2 of power supply to be injected, or external terminal.) |
VARIABLE | 10ms ~ 999ms ±10% |
EXT | >10ms TTL/Open collector negative logic |
1 SHOT | By trigger switch, a single pulse injection to any phase angle of the power line |
Power capacity of EUT | AC240V Single phase, DC60V, 16A |
Power supply | 100 ~ 240 VAC 50/60 Hz |
Power consumption | 140VA |
Operating temperature and humidity | 15 ~ 35°C 25 ~ 75% (No dewing shall occur.) |
Dimensions and weight | (W)430 x (H)249 x (D)420 mm (Projections excluded) / Approx. 19 kg |