Skip to Content

ATEC’s Leading Large-Scale Equipment Choices

Learn more and request a quote by selecting a product.
*Scroll down to view all products and categories*

Take advantage of 20% savings on rental orders placed before 01/31/2026.
Interested in owning? Select units are ready for purchase—contact us today.

Power Supplies

California Instruments Sequoia SQ0090 Regenerative AC Grid Simulator

  • Frequency Range
    • 16 – 905 Hz with HF option (DC)
  • Voltage Range
    • Low Range: 0 – 220 VDC
    • High Range: 0 – 440 VDC
  • Output Power
    • 90kVA / 90kW
      1 or 3Φ
ITECH IT79165-350-990

ITECH IT79165-350-990 Regenerative Grid Simulator

  • Voltage range (L-N)
    • 350V
  • Current range (Arms)
    • 1Ø: 990A
    • 3Ø: 330A
  • Power
    • 165kVA
  • Height
    • 37U

NH Research 9510-100 Regenerative Grid Simulator

  • Frequency Range
    • Up to 100 kW
  • Operating Modes
    • 4-Quadrant with Programmable Voltage (CV), Power Amplifier (PHIL), Optional AC Load
  • Power, Max (1Φ or 3Φ)
    • 100kW/236kVA
  • Current Ranges (RMS per Φ)
    • 50, 225 A

NH Research 9300-100 High-Voltage Battery Test System

  • Power Rating
    • 100 kW
  • Max. Current @ 600 V
    • 333 A
  • Current @ 1200 V
    • ±167 A

Pacific Power 315ASX High Performance AC Power Source

  • Frequency Range
    • 15 – 1200 Hz
  • Output Power
    • 1500 VA with selectable 1, 2, or 3-phase AC output
  • Output voltage range
    • Up to 132V/264V (single/two-phase)
    • 132/228V (three-phase)

Kikusui PLZ1004W Multifunction DC Load

Maximum Power
1000 W (1 kW)
Max Current
200 A
Operating Voltage Range
1.5 V to 150 V DC
Input Frequency Range
47 – 63 Hz

NH Research 9430-12 Regenerative 4-Quadrant AC Load

  • Phases/Output Channels
    • Single, Split or 3-Phase
  • Input Voltage (LR,HR)
    • 10 – 175, 350 VRMS L-N (split-phase limited to 250 V max)
  • Current Limit, Set Ranges (per ф)
    • 0 – 6,
      30 A (3ф)
  • Input Voltage
    • 10 – 400 VDC

Pacific Power 3150AFX AC & DC Programmable Power Source

  • Frequency Range
    • 15 - 1200 Hz
  • Output Power
    • 15 kVA
  • AC Voltage Range
    • 0 – 300 VRMS L-N / 0 – 520 VRMS L-L constant power mode
  • DC Voltage Range
    • 0 – 425 VDC constant power mode
  • Phase Output Modes
    • Single (1), Split (2), and three phase (3)

Chroma 61860 Regenerative Grid Simulator

  • Frequency Range
    • 30 ~ 100 Hz
  • Output Phase
    • 1 or 3 selectable
  • Max. Power
    • 60 kVA
    • 20 kVA per phase
  • Output Voltage (per phase)
    • 0 – 300 VLN

Pacific Power 115ASXT AC Power Source, 1.5 kV

  • Frequency Range
    • 15 - 1200 Hz
  • Rated Power
    • 1500 VA
  • Output Voltage
    • 132 Vrms Max

Kikusui PCZ1000A AC Electronic Load

  • Operating Voltage
    • 14 - 280Vrms
    • 20 - 400Vpeak
  • Max Current
    • 10Arms
    • 40Apeak
  • Max power
    • 1000W
  • Frequency
    • 45 - 65Hz

Pacific Power 125AMX Single Phase Linear AC Power Source

  • Frequency
    • 20 Hz – 5 kHz (Direct Coupled)
    • 45 Hz – 5 kHz (Transformer Coupled)
  • Line Regulation
    • 0.1% max for a ±10% line change
  •  Load Regulation
    • 0.25% 20 to 2,000 Hz
    • 0.50% 2,000 to 5,000 Hz
  • Ripple and Noise
    • -72dB

Keysight SL1215A Scienlab Regenerative AC / Grid Simulator

  • Frequency Range
    • 40 – 75 Hz
  • Voltage Range
    • 600V / 1200V
  • Max Current
    • 130A / 65 A

Pacific Power 360AMX AC Power Supply

  • Frequency Range
    • 20 - 5000 Hz
  • Max Output Voltage
    • 135/270 Vrms, 135 (L-N)
  • Rated Power
    • 6000 VA

EMC

Haefely PSURGE 30.2 Surge Test System

  • Charging voltage range
    • 3 – 33 kV
  • Capacitors
    • 9 uF / 36 uF
  • Stored energy
    • 5 kJ at max. charging voltage

Teseq NSG 3060 Transient Generator

  • Surge Combo Wave Pulse (IEC/EN 61000-4-5 and ANSI (IEEE) 62.41)
    • Pulse voltage (open circuit): 200 V – 6.6 kV (in 1 V steps)
    • Pulse current (short circuit): 100 A – 3.3 kA
    • Impedance: 2/12 Ω
  • Burst (EFT) 5/50 ns (IEC/EN 61000-4-4)
    • Pulse amplitude: 200 V – 4.8 kV (in 1 V steps) - open circuit / 100 V – 2.4 kV (50 Ω matching system)
    • Burst frequency: 100 Hz – 1000 kHz
    • Burst time: 1 µs – 1999 s, single pulse, continuous
  • PQF Dips & Drops (IEC/EN 61000-4-11, IEC/EN 61000-4-29)
    • Dips & Interrupts: From EUT voltage input to 0 V, 0%
    • Peak inrush current capability: 500 A (at 230 V)
    • Switching times    1 – 5 μs (100 Ω load)

M Precision Laboratories EMCPro PLUS EMC Test System

  • System Voltage
    • 90 – 240 VAC, 50/60 Hz
  • AC Voltage
    • 1 phase, 50 – 250 VAC, 50/60 Hz
  • AC Current
    • 16 A max.
  • DC Voltage
    • 100 VDC max.

Teseq NSG 3040 Transient Generator

  • Surge Combo Wave Pulse Pulse (IEC/EN 61000-4-5)
    • Pulse voltage (open circuit): 200 V – 4.4 kV (in 1 V steps)
    • Pulse current (short circuit): 100 A – 2.2 kA
    • Impedance: 2/12 Ω
  • Burst (EFT) 5/50 ns (IEC 61000-4-4)
    • Pulse amplitude: 200 V – 4.8 kV (in 1 V steps) - open circuit / 100 V to 2.4 kV (50 Ω matching system)
    • Burst frequency: 100 Hz – 1000 kHz
  • PQF Dips & Drops (IEC/EN 61000-4-11, IEC/EN 61000-4-29)
    • Dips & drops: From EUT voltage input to 0 V, 0%
    • Peak inrush current capability: 500 A (at 230 V)
    • Switching times: 1 – 5 μs (100 Ω load)
ilac MRA, A2LA, ISO logos

ISO/IEC 17025:2017 Accreditation

ATEC’s calibration laboratory is accredited to ISO/IEC 17025:2017 by A2LA, Certificate Number 3410.01, for specific calibrations in the EMC, RF, and electrical/AC & DC fields.

ATEC is both ISO 9001 certified and ISO 17025 accredited to perform NIST and 17025 calibrations respectively. While not all equipment or services fall under this scope, it enables us to provide trusted calibration services supporting our broad inventory of test equipment.

All calibrations are performed at ATEC HQ in San Diego, CA.