The Haefely PEFT 8010 instrument contains all the features expected from a top quality EFT generator. Unbeaten performance paired with a high end assembly guarantee a cost effective, long-lasting investment and valuable test results.
PEFT 8010 can either be operated by the front panel keys in a stand alone manner or be controlled by PC via RS232 or IEEE 488 as part of a complete EMC test system.
Features
- EFT impulse generation according to newest standards and latest technology.
- ESD control and report functions for attaching an Electrostatic Discharge gun.
- Automatic test operation for shortest measuring time and minimal setup effort.
- Compact and reliable construction for factory, laboratory or field use.
- Remote control is provided by optional software (WinFEAT&R) designed specially for EMC testing.
- ISO 9001 : 2000 certified manufactured
Specifications
Wave Shape into 50 ohm load |
Rise time |
5 ns ± 30 % |
Impulse duration |
50 ns ± 30 % |
Wave Shape into 1000 ohm load |
Rise time |
5 ns ± 30 % |
Impulse duration |
50 ns – 15 / + 100 ns |
Burst Characteristic |
Voltage at HV-output:
Voltage at CDN output: |
1.0 … 7.3 kV
1.0 … 6.6 kV |
Spike frequency |
1 Hz … 110 kHz |
Burst duration |
0.01 … 999 ms |
Burst period |
0.1 Hz … 400 Hz
2.5 ms … 10 s
1 period … 500 periods |
Impulses per second |
max. 250 for Unom > 4 kV
max. 500 for Unom ≤ 4 kV |
Impulses per burst |
max. 75 for Unom > 4 kV
max. 150 for Unom ≤ 4 kV |
Spike distribution |
normal, continuous, random, real |
Polarity |
positive, negative |
Test time |
10 s … 8 h per path |
Single Phase Coupling/Decoupling Network |
Maximum AC voltage |
264 V @ 16 … 440 Hz |
Maximum AC current |
16 A @ 50 … 60 Hz, 10 A @ 400 Hz |
Maximum DC voltage |
125 V |
Coupling Modes |
L-GND, N-GND, PE-GND, LN-GND, LPE-GND, NPEGND, LNPE-GND |
Residual voltage at Test Supply Input |
≤ 10% of applied test voltage |
Synchronization |
Frequency |
16 2/3 Hz, 40 Hz, 50 Hz, 60 Hz, 400 Hz, auto |
Impulse trigger |
automatic, manual, external |
System Configuration |
EUT fail input |
BNC, logic low to trigger |
P90 interface |
for a 3-phase CDN extension |
PESD interface |
for connecting an ESD generator |
Printer interface |
Centronix |
Computer interface |
RS-232, IEEE-488 (optional) |
Power Supply |
Voltage |
85 … 264 VAC, 150 VA |
Frequency |
50 / 60 Hz |
Weight and Dimension |
Weight |
14 kg |
W x H x D |
450mm x 130mm x 570mm |
Applications
- Approval Testing
- Product Development
- Post Design Diagnostics
- Industrial
- Medical
- Telecommunication
- Household