Related Products

EMC Partner MIL-MG3 Military Test System
- Exceeds maximum test levels in MIL-STD-461
- One coupler for tests (CS115 & CS116)
- Test report data stored in MIL-MG3, accessible via USB or Ethernet


AE Techron DSR 100-200 | Pulse 2B and 4
- Frequency Range: DC - 250 kHz
- Output Current: 0A - 200A (Cont.)
- DO 160G, ISO 7637-2, MIL STD 461F


Montena PPG-E1-1200 Portable Pulse Generator for MIL-STD-188-125
- A wide operating range from 50 A to 1.2 kA
- Dedicated control software application for the configuration of the generator and the measurement equipment
- Battery powered, especially designed for tests onsite


EM Test UCS 200N50 Automotive Transient Generator
- EFT/Burst: 25V – 1,000V ±10%
- 60V / 50A continuous, 100A @ 500 ms
- ISO 7637-2 Pulses 1, 2, 3A/3B, 6


Solar 2654-2 Lightning Transient Generator System for DO-160
- The controller and power supply module
- Waveform timing
- The high voltage power supply


Solar Electronics 7399-3 Spike Generator
- Repetitive spikes up to 2500 V peak at two pulses per minute
- Single non-synchronous spike actuated by a pushbutton on the panel
- Sync functions provide for placing the spike on the power frequency waveform of 50, 60 or 400 Hz power lines; the spike can be moved to any point on the sine wave from 0 to 360°


Solar 9354-1
- Panel mounted digital Voltmeter displays the open circuit discharge voltage
- Automatic or manual trigger for damped sinewave. Manual only for double exponential pulses
- Variable peak output voltage (adjustable from 0.1 to 100% of selected circuit discharge voltage


AE Techron 3110 Standards Waveform Generator
- DC-20kHz (DAC), DC-300kHz (Sine)
- 120VAC, 1.0VA service, 1Ø
- IEC 6100-4-16, ISO 7637, ISO 16750-2


Solar 9354-2 Transient Generator for MIL-STD-461 and DO-160
- Panel-mounted digital voltmeter. Monitors the adjusted open circuit discharge voltage
- Pulse rates up to one pulse per second maximum (factory adjusted)
- Single pulse feature enables controlled isolation of transient effects


Hilo-Test CAR Test System 14
- Rise time variable 1 - 5µs.
- Vehicle voltages : 12V / 24V / 42V / 48V / 70V.
- Battery current: 50A / 100A / 200A.


EM Test VDS 200N100 Voltage Drop Simulator 60 V, 100 A
- Voltage up to 60 V
- Current up to 100A
- Bipolar-amplifier models available


EM Test PFM 200N100.1 Automotive Power Fail Simulator
- Switch for Power supply (100 A) and signal/data lines (2 A)
- Pulses E10 and E13 of the LV 124/LV 148 standard
- Bidirectional current direction


Montena PG1275 Surge Generator
- Standard: MIL-STD-1275D
- Transients supported: imported and exported spikes imported and exported surges
- imported and exported spikes


Solar 7054-2B Spike Generator
- 0° to 360°
- Periodically 50, 60 or 400 Hz Sine Wave
- Provides output levels from 10 V to 400 V into 5 Ω. Delivers more than 300 kW peak into 0.5 Ω load


Solar 9355-1 for MIL-STD-461D/E CS115
- Panel-mounted digital meters monitor the adjustable charged line voltage and pulse repetition rate.
- Adjustable pulse rate from 0.6 p.p.s. to 150 p.p.s., and manual triggering via front panel push button.
- Charged line output voltage adjustable from 1.0 V to >2000 V


Solar 7399-2 2,500 Volt Spike Generator for MIL-STD-1399
- Repetitive spikes up to 2500 volts peak at two pulses per minute.
- Single non-synchronous spike actuated by a push button on the panel.
- Sync functions provide for placing the spike on the power frequency waveform of 50, 60 or 400 Hz power lines. The spike can be moved to any point of the sine wave from 0 to 360°


Hilo-Test CAR PG 2804 Load Dump Generator
- Load Dump Generator.
- Pulse #5 / Test A / Test B.
- Ri = 0.5 / 1 / 2 / 4 / 8 Ω


EM Test LD 200N Load Dump Generator
- Pulse Duration: 10 ms - 1200 ms
- Rise time: <1 µs - 10 ms
- Internal resistance: 0.5 - 38 Ω


EM Test Autowave Arbitrary Generator
- Dual-Processor-Technology, 500kS/s sample rate
- 4-channel arbitrary generator
- 2-channel transient recorder


Teseq NSG 4070B Conducted Immunity Test System
- Amp Range: 150kHz - 230MHz (80W)
- Sig Gen Range: 9kHz - 1GHz
- 3 Power Meter Ports


Schwarzbeck NNBL-8240
- Max Current: 800A
- Voltage (50/60Hz): 650V
- Impedance: 50µH + 5Ω || 50Ω ±20%


EM Test PFS 200N Series Automotive Power Fail Simulator
- Standalone test generator for voltage dips and interruptions
- Rise/fall time <1us
- Electronic short-circuit protection


Hilo-Test CAR-AWG 1200 Battery Simulator
- For electrical installation of vehicles
- Battery simulator
- Bandwidth DC-200kHz


Solar 2854-2 Spike Generator
- Provides output levels from 10 V to more than 400 V into 5 Ω
- Adjustable pulse position on AC lines relates the transient susceptibility to real time aspects of digital systems
- Single pulse feature for controlled isolation of transient eects


Solar Electronics 9554 Variable Frequency Modules
- Variable frequency modules
- Comes in several configurations
- Specialized module for military and aerospace applications