Manta MTS-1400 Transducer Calibration System

Rent Manta MTS-1400 Transducer Calibration System
Enlarge Image
Request Quote Print Page

The Manta MTS-1400 Transducer Calibration System has the following:

Features:

  • Calibrate voltage, current, Watt, VAr and frequency transducers
  • Calibrate all single and three phase power transducers
  • Direct display of percent error
  • Connect up to 9 transducers simultaneously
  • Semi-automated or fully automated testing capable

Specifications:

Power Supply
  • Single phase 108-133 VAC/60Hz (or 216-264 VAC/50Hz), 200VA max, factory set
 
 
Single phase AC voltage
  • 0-155V rms, 15 VA maximum
  • Accuracy +/-0.1%of full scale +/-2 least significant digits, for 10%-100% of full scale
  • Four color coded output terminals, A, B, C, N provided.
  • Selectable phase-phase (A-B, C-B, C-A) or phase-neutral (A-N, B-N, C-N) output
  • All phase-neutral, or A-B plus C-B outputs, may be selected simultaneously
 
 
Single phase AC current
  • 0-6A rms, 18 VA maximum
  • Accuracy +/-0.1%of full scale +/-2 least significant digits, for 10%-100% of full scale
  • Three pairs of color coded output terminals, A, B, C provided.
  • Each phase output and polarity independently controllable, and group reverse switch provided