Output Voltage: |
Two variable: | 0 to 30 VDC |
One fixed: | 5.0 V |
Output Current: |
Two variable: | 0 to 2.0 A (CC)*1 |
One fixed (foldback limited): | 3.0 A max |
Line Regulation: |
Two variable: | 0.01% +3 mV (CV); 0.2% + 3 mA (CC) |
One fixed: | ≤5 mV (CV) |
Load Regulation: |
Two variable: | ≤0.01% + 5 mV, current >3 A (CV); ≤300 mV 0 to 60 V single series tracking supply (CV), 0.2% +3 mA (CC) |
One fixed: | ≤10 mV (CV) |
Ripple/Noise: |
Two variable: | ≤1 mVRMS, 5 Hz to 1 MHz (CV); ≤3 mA (CC) |
One fixed: | ≤2 mVRMS |
Output in Independent Mode: |
Two variable: | 0 to 30 V (CV); 2.0 A (CC) |
Output in parallel mode: | One 0 to 30 V, 4.0 A max |
Tracking error: | ≤0.5% + 10 mV |
Series mode: | One 0 ±30 V, 2.0 A max or one 60 V, 2 A |
Tracking error: | ±0.5% +10 mV |
Displays: | Two 3-1/2 digit LED (switchable) |
Voltage indicators: | 0 to 30 VDC ±(0.5% of rdg + 2 digits) |
Current indicator: | 0 to 2 A DC ±(0.5% of rdg + 2 digits) |
Overload indicator: | Yes |
Insulation: |
Chassis to terminal: | ≥20 MΩ at 500 VDC |
Chassis to power cord: | ≥30 MΩ at 500 VDC |
Safety: | UL1244, CSA231, EN61010-1, Denturi Mark |
EMC: | Meets Directive 89/336/EEC |
*1 (CC): When operated in constant current mode. (CV): When operated in constant voltage mode.