Teseq CDND M316-2 Coupling/Decoupling Network for Differential Mode

Rent Teseq CDND M316-2 Coupling/Decoupling Network for Differential Mode
Enlarge Image
Request Quote Print Page
Datasheet
IEC / EN 61000-4-19 specifies the differential voltage test in the frequency range 2 kHz to 150 kHz. Teseq offers with CDND M316-2 a coupling / decoupling network for single phase mains application. It can be used for both application with and without protective earth connection. The CDND is fully complaint with the requirements of the standard and provides a simple and reliable method of injecting RF energy into the equipment under test (EUT).
 

Teseq CDND M316-2 Features:

 
  • Coupling networks designed for voltage test IEC/EN 61000-4-19
  • Frequency range 2 kHz to 150 kHz
  • 4 mm banana sockets
  • M2 and M3 applications
 

Teseq CDND M316-2 Specifications:

 
Frequency range: 2 kHz to 150 kHz
Power rating (EUT- and Mains port)
AC max. voltage (line to line / line to ground): 250 V / 500 V (50 Hz / 60 Hz)
DC max. voltage (line to line / line to ground): 400 V / 500 V
Current max: 16 A
Test voltage: 1500 V DC, 2 sec
Common mode impedance (EUT port)
2 kHz to 150 kHz: 10 Ω ±3 Ω
Coupling path (Generator / EUT port)
Connection: 4 mm banana
RF voltage (2 kHz to 150 kHz): <22 V
Voltage drop (Mains port to EUT port)
at 16 A DC: approx. 2.6 V
at 16 A AC (50 Hz): approx. 18 V
Decoupling of CM disturbance (Mains port / EUT port)
2 kHz to 50 kHz: >10 dB to >50 dB
50 kHz to 150 kHz: >50 dB