Thermo Keytek EMC Pro Advanced EMC Test System

Rent Thermo Keytek EMC Pro Advanced EMC Test System
Enlarge Image
Thermo Fisher Scientific Thermo Keytek EMCPro
Request Quote Print Page
Specifications

The answer to manufacturers' demand for a mid-range, multi-capability EMC immunity tester, EMCPro® is easily configured to meet today's immunity standards required for CE Marking and compliance requirements. Operating via Thermo KeyTek's easy to use Windows®-based PC software or from the front panel, it enables test engineers and technicians to run compliance-level EMC immunity tests in accordance with European Norm requirements. Portable and low cost, the EMCPro® is ideal for companies who require flexibility, versatility, and the highest test level-to-cost ratio instrument on the market.
 

Configurations for the Keytek EMCPro:

Model PRO-SURGE
Surge per IEC 61000-4-5. Will do part of UL1449
Voltage Waveform 1.2/50µs
Peak Voltage 250V - 6.6kV ±5%, 12Ω Mode
250V - 6.0kV ±5%, 2Ω mode
Peak Current 125 A - 3.3 kA ±10%
Additional 10 ohm Resistor Software selectable
Repetition Rate Up to 4 per minute
Open-circuit Voltage Front time: 1.2µs ±30%
Duration: 50µs ±20%
Undershoot: ≤30%
Line sync accuracy ±15%, 50 - 277 VAC
Model PRO-EFT
EFT per IEC 61000-4-4 and ANSI
Voltage Waveform 5/50 ns ±30%
Peak Voltage 250V - 4.4 kV ±5%
Burst Period 300 ms ±10%
Burst Duration 15 ms ±20%
Frequency 1 kHz - 100 kHz in 0.5 kHz steps, ±10%
DC Blocking Capacitor 10 nF (internal)
Model PRO-RING*
Surge Ring Wave per ANSI and UL. Will do part of 61000-4-12.
Voltage Waveform 100 kHz damped cosine
Peak Voltage 250 - 6.6kV ±5%
Repetition Rate <4/minute at 6 kV, faster at lower voltages
Open-circuit Voltage Rise Time: 0.5µs ±30%
Short-circuit Current Vp/Ip: 12 ohm ±3 ohm or 30 ohm ±8 ohm software selectable
*Pro-Telecom and Pro-Ring can not be installed together in the same unit
Surge Waveform Monitoring
Lines Monitored Monitors are automatically switched to match the generator coupling mode
Open-circuit Voltage 1000:1 ±10%
Short-circuit Current Attenuation: 200:1 ±7%
Model PRO-HPOWER
Power Frequency Magnetic Field per 61000-4-8
Field Frequency 50Hz/60Hz
Field Amplitude 0.5-4A/m, in 0.25A steps, ±10% (with CM-HCOIL) up to 100A/m with the optional external HPOWER-EXT
AC Source Internal
Resolution 0.25 Amp minimum
Coil Factor 0.65 to 1.00
Coil Resistance 0.05Ω maximum
Model PRO-HPULSE
Pulse Magnetic Field per IEC 61000-4-9
Field Pulse 8/20µs
Field Amplitude 100A/m -1000A/m, ±10%
Resolution 5A/m
Coil Factor 0.65 to 1.00
Model PRO-PQF
Dips and Interrupts per IEC 61000-4-11
Dips 70%, 40%
Interrupts 0% (short and open)
Transition Time 1µs - 5µs
Inrush Minimum: 250 Amps @ 100V - 120V
Minimum: 50 0Amps @ 220V - 240V
AC Voltage 50 VAC - 250 VAC, 50 Hz - 60 Hz
AC Current 16A Max
PQF Sync Output 5V signal occurs at each Dip or interrupt transition
Dip Duration 10 msec min at 60 Hz
2 msec min at 50 Hz
PQF Waveform Monitoring
Voltage Input Connection Fixed, L1 to L2
Voltage Attenuation 100:1 ±5%
Current Input Connection Fixed, L1
Peak Current Minimum 500A inrush into 1700µF
Current Attenuation 200:1 ±5%
Model PRO-BASE
System Voltage 90 VAC - 240 VAC, 50 Hz - 60 Hz
Integrated EUT Mains Coupler/Decoupler AC Voltage: 1 phase, 50-250VAC, 50/60Hz
AC Current: 16A max
DC Voltage: 100 VDC max
DC Current: 10A max
Frequency: 50/60Hz
EUT Connectors: Nema, British, Schuko
Control Interface: RS232 Fiber-optic
Safety Features: External Interlock for users
Interlock for CCL connector
External stop input